Projects per year
Infrastructure Details
Acronym
Flow Cytometry Core Facility at LUDC
Description
The Flow Cytometry Core Facility at LUDC provides instrumentation and technical assistance to perform analysis using flow cytometry and operator based cell sorting service to all Lund University scientists as well as scientists from other institutes and industry.
Our facility houses one state-of-the-art cell sorter, two analysers and one multiplex analyser. Find more details on the facility's webpage:
https://www.ludc.lu.se/resources/flow-cytometry-core-facility-at-ludc
Our facility houses one state-of-the-art cell sorter, two analysers and one multiplex analyser. Find more details on the facility's webpage:
https://www.ludc.lu.se/resources/flow-cytometry-core-facility-at-ludc
Equipment and resources
For more details please visit: Cell sorter
https://www.ludc.lu.se/resources/flow-cytometry-core-facility/instruments
Cell sorter
BD FACS Aria Fusion
4 lasers (405, 488, 561, 640 nm)
16 fluorescence parameters
Acquisition tubes: 1.5, 5, or 15 ml tubes
Collection: 1.5, 2, 5 or 15 ml tubes or 6-, 12, 24-l, 48-, 96- or 384-well plates
Bulk sorts up to 4 population simultanesouly or single cell sorts
Temperature controlled options
Cell Analyzers
CytoFLEX
3 lasers (405, 488, 640 nm)
13 fluorescence parameters
Acqusition tubes: 1.5 or 5 ml tubes
High throughput 96-well plate unit
Gallios
3 lasers (405, 488, 638 nm)
10 fluorescence parameters
Acquisition tubes: 5 ml tubes
32 tube Multi Carousel Loader (MCL)
Luminex
Up to 100 analyts simultaneously
Very small sample volume
High throughput 96-well plate unit
https://www.ludc.lu.se/resources/flow-cytometry-core-facility/instruments
Cell sorter
BD FACS Aria Fusion
4 lasers (405, 488, 561, 640 nm)
16 fluorescence parameters
Acquisition tubes: 1.5, 5, or 15 ml tubes
Collection: 1.5, 2, 5 or 15 ml tubes or 6-, 12, 24-l, 48-, 96- or 384-well plates
Bulk sorts up to 4 population simultanesouly or single cell sorts
Temperature controlled options
Cell Analyzers
CytoFLEX
3 lasers (405, 488, 640 nm)
13 fluorescence parameters
Acqusition tubes: 1.5 or 5 ml tubes
High throughput 96-well plate unit
Gallios
3 lasers (405, 488, 638 nm)
10 fluorescence parameters
Acquisition tubes: 5 ml tubes
32 tube Multi Carousel Loader (MCL)
Luminex
Up to 100 analyts simultaneously
Very small sample volume
High throughput 96-well plate unit
Services provided
The facility provides:
Access to state-of-the-art cell analyser
Operator based cell sorting service
On site training for the cell analyzer
Technical support
Assistance with experimental design, data anayzer and interpretation
Assistance in developing novel ulticolor flow cytometric techniques
Performing of flow cytometric experiments
Access to state-of-the-art cell analyser
Operator based cell sorting service
On site training for the cell analyzer
Technical support
Assistance with experimental design, data anayzer and interpretation
Assistance in developing novel ulticolor flow cytometric techniques
Performing of flow cytometric experiments
Management of the infrastructure
Head of facility and point of contact:
Monika Dudenhöffer-Pfeifer, PhD
Associate Researcher
Bookings and Cancellations
Cell Sorter
For cell sorting request, please, contact the head of the facility.
Cell Analysers
Approved users can book the different instruments in the Flow Cytometer Core Facility online calendar.
In order to get an approved user it is very important to have a basic knowledge in flow cytometry. Appropriate literature or links can be found under ´links´. With a good basci knowledge the user can book an instruction session via email followed by an on site training with users´s samples.
Cancellation should be done at least 24 hours prior the booking.
Monika Dudenhöffer-Pfeifer, PhD
Associate Researcher
Bookings and Cancellations
Cell Sorter
For cell sorting request, please, contact the head of the facility.
Cell Analysers
Approved users can book the different instruments in the Flow Cytometer Core Facility online calendar.
In order to get an approved user it is very important to have a basic knowledge in flow cytometry. Appropriate literature or links can be found under ´links´. With a good basci knowledge the user can book an instruction session via email followed by an on site training with users´s samples.
Cancellation should be done at least 24 hours prior the booking.
Subject classification (UKÄ)
- Medical and Health Sciences
Type of infrastructure
- Equipment
- Services
Projects
- 1 Active
-
Immunological markers of type 1 diabetes pathogenesis prior to clinical diagnosis
Andersson Svärd, A. (Researcher)
2017/07/01 → …
Project: Dissertation