A chemiluminescence flow immunosensor based on a porous monolithic metacrylate and polyethylene composite disc modified with Protein G

Seema Rani Jain, Ewa Borowska, Richard Davidsson, Madalina Tudorache, Einar Pontén, Jenny Emnéus

Research output: Contribution to journalArticlepeer-review

Abstract

A generic, fast, sensitive and new type of flow immunosensor has been developed. The basis is a monolithic porous poly(glycidyl methacrylate-co-trimethylolpropane trimethacrylate) polymer disc modified with protein G, placed in a fountain type flow cell compartment, in close proximity to a photomultiplier tube (PMT). Analyte and HRP labelled analyte derivative (tracer) compete for anti-analyte antibody binding sites. The mixture is then injected into the flow immunosensor system where the formed analyte- and tracer-antibody complexes are trapped by the monolithic protein G disc. The amount of bound tracer, inversely related to the concentration of analyte in the sample, is determined in a second step by injection of luminol, p-iodophenol and H2O2, generating enhanced chemiluminescence (CL) with horseradish peroxidase (HRP). A third and final step is need for regeneration of the protein G disc so that a new analysis cycle can take place. The performance of the disc immunosensor system was compared with a one step continuous flow injection immunoassay (FIIA) system, using the same reagents and a protein G column, in terms of assay sensitivity and influence of matrix effects from various water samples (millipore-, tap- and surface water). The detection limit for the analyte atrazine in PBS and surface water (SW) was 0.208±0.004 g l−1 (PBS) and 0.59±0.120 g l−1 (SW) for the FIIA and 0.033±0.003 g l−1 (PBS) and 0.038±0.003 g l−1 (SW) for the disc immunosensor. Statistical comparison of the two systems shows that the disc immunosensor results were significantly less influenced by the sample matrix, which is explained by the fact that the sample in the FIIA arrives simultaneously with the matrix to the detector, whereas these are separated in time in the disc immunosensor system.
Original languageEnglish
Pages (from-to)795-803
JournalBiosensors & Bioelectronics
Volume19
Issue number8
DOIs
Publication statusPublished - 2004

Bibliographical note

The information about affiliations in this record was updated in December 2015.
The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)

Subject classification (UKÄ)

  • Analytical Chemistry

Free keywords

  • Solid phase reactor
  • Protein G
  • Monolith
  • Immunosensor
  • Chemiluminescence
  • Atrazine

Fingerprint

Dive into the research topics of 'A chemiluminescence flow immunosensor based on a porous monolithic metacrylate and polyethylene composite disc modified with Protein G'. Together they form a unique fingerprint.

Cite this