TY - JOUR
T1 - A new automated method for analysis of rCBF-SPECT images based on the active-shape algorithm: normal values.
AU - Hägerström, Douglas
AU - Jakobsson, David
AU - Stomrud, Erik
AU - Andersson, Ann-Margret
AU - Ryding, Erik
AU - Londos, Elisabet
AU - Minthon, Lennart
AU - Rosén, Ingmar
AU - Edenbrandt, Lars
PY - 2012
Y1 - 2012
N2 - Most nuclear medicine clinicians use only visual assessment when interpreting regional cerebral blood flow (rCBF) from single-photon emission computed tomography (SPECT) images in clinical practice. The aims of this study were to develop a new, easy to use, automated method for quantification of rCBF-SPECT and to create normal values by using the method on a normal population. We developed a 3-dimensional method based on a brain-shaped model and the active-shape algorithm. The method defines the surface shape of the brain and then projects the maximum counts 0-1·5 cm deep for designated surface points. These surface projection values are divided into cortical regions representing the different lobes and presented relative to the whole cortex, cerebellum or cerebellar maximum. (99m) Tc-hexa methyl propylene amine oxime (HMPAO) SPECT was performed on 30 healthy volunteers with a mean age of 74 years (range 64-98). The ability of the active-shape algorithm to define the shape of the brain was satisfactory when visually scrutinized. The results of the quantification show rCBF values in the frontal, temporal and parietal lobes of 87-88% using cerebellum as the reference. There were no significant differences in normal rCBF values between male and female subjects and only a weak relation between rCBF and age. In conclusion, our new automated method was able to quantify rCBF-SPECT images and create normal values in ranges as expected. Further studies are needed to assess the clinical value of this method and the normal values.
AB - Most nuclear medicine clinicians use only visual assessment when interpreting regional cerebral blood flow (rCBF) from single-photon emission computed tomography (SPECT) images in clinical practice. The aims of this study were to develop a new, easy to use, automated method for quantification of rCBF-SPECT and to create normal values by using the method on a normal population. We developed a 3-dimensional method based on a brain-shaped model and the active-shape algorithm. The method defines the surface shape of the brain and then projects the maximum counts 0-1·5 cm deep for designated surface points. These surface projection values are divided into cortical regions representing the different lobes and presented relative to the whole cortex, cerebellum or cerebellar maximum. (99m) Tc-hexa methyl propylene amine oxime (HMPAO) SPECT was performed on 30 healthy volunteers with a mean age of 74 years (range 64-98). The ability of the active-shape algorithm to define the shape of the brain was satisfactory when visually scrutinized. The results of the quantification show rCBF values in the frontal, temporal and parietal lobes of 87-88% using cerebellum as the reference. There were no significant differences in normal rCBF values between male and female subjects and only a weak relation between rCBF and age. In conclusion, our new automated method was able to quantify rCBF-SPECT images and create normal values in ranges as expected. Further studies are needed to assess the clinical value of this method and the normal values.
U2 - 10.1111/j.1475-097X.2011.01063.x
DO - 10.1111/j.1475-097X.2011.01063.x
M3 - Article
C2 - 22296631
SN - 1475-0961
VL - 32
SP - 114
EP - 119
JO - Clinical Physiology and Functional Imaging
JF - Clinical Physiology and Functional Imaging
IS - 2
ER -