TY - JOUR
T1 - A sensitive and simple ultra-high-performance-liquid chromatography-tandem mass spectrometry based method for the quantification of d-amino acids in body fluids
AU - Visser, Wouter F.
AU - Verhoeven-Duif, Nanda M.
AU - Ophoff, Roel
AU - Bakker, Steven
AU - Klomp, Leo W.
AU - Berger, Ruud
AU - De Koning, Tom J.
PY - 2011/10/7
Y1 - 2011/10/7
N2 - d-Amino acids are increasingly being recognized as important signaling molecules in mammals, including humans. d-Serine and d-aspartate are believed to act as signaling molecules in the central nervous system. Interestingly, several other d-amino acids also occur in human plasma, but very little is currently known regarding their function and origin. Abnormal levels of d-amino acids have been implicated in the pathogenesis of different diseases, including schizophrenia and amyotrophic lateral sclerosis (ALS), indicating that d-amino acid levels hold potential as diagnostic markers. Research into the biological functions of d-amino acids is hindered, however, by the lack of sufficiently sensitive, high-throughput analytical methods. In particular, the interference of large amounts of l-amino acids in biological samples and the low concentrations of d-amino acids are challenging. In this paper, we compared 7 different chiral derivatization agents for the analysis of d-amino acids and show that the chiral reagent (S)-NIFE offers outstanding performance in terms of sensitivity and enantioselectivity. An UPLC-MS/MS based method for the quantification of d-amino acids human biological fluids was then developed using (S)-NIFE. Baseline separation (R s>2.45) was achieved for the isomers of all 19 chiral proteinogenic amino acids. The limit of detection was <1nM for all amino acids except d-alanine (1.98nM), d-methionine (1.18nM) and d-asparagine (5.15nM). For measurements in human plasma, cerebrospinal fluid and urine, the accuracy ranged between 85% and 107%. The intra-assay and inter-assay were both <16% RSD for these three different matrices. Importantly, the method does not suffer from spontaneous racemization during sample preparation and derivatization. Using the described method, d-amino acid levels in human cerebrospinal fluid, plasma and urine were measured.
AB - d-Amino acids are increasingly being recognized as important signaling molecules in mammals, including humans. d-Serine and d-aspartate are believed to act as signaling molecules in the central nervous system. Interestingly, several other d-amino acids also occur in human plasma, but very little is currently known regarding their function and origin. Abnormal levels of d-amino acids have been implicated in the pathogenesis of different diseases, including schizophrenia and amyotrophic lateral sclerosis (ALS), indicating that d-amino acid levels hold potential as diagnostic markers. Research into the biological functions of d-amino acids is hindered, however, by the lack of sufficiently sensitive, high-throughput analytical methods. In particular, the interference of large amounts of l-amino acids in biological samples and the low concentrations of d-amino acids are challenging. In this paper, we compared 7 different chiral derivatization agents for the analysis of d-amino acids and show that the chiral reagent (S)-NIFE offers outstanding performance in terms of sensitivity and enantioselectivity. An UPLC-MS/MS based method for the quantification of d-amino acids human biological fluids was then developed using (S)-NIFE. Baseline separation (R s>2.45) was achieved for the isomers of all 19 chiral proteinogenic amino acids. The limit of detection was <1nM for all amino acids except d-alanine (1.98nM), d-methionine (1.18nM) and d-asparagine (5.15nM). For measurements in human plasma, cerebrospinal fluid and urine, the accuracy ranged between 85% and 107%. The intra-assay and inter-assay were both <16% RSD for these three different matrices. Importantly, the method does not suffer from spontaneous racemization during sample preparation and derivatization. Using the described method, d-amino acid levels in human cerebrospinal fluid, plasma and urine were measured.
KW - (S)-NIFE
KW - Chiral derivatization
KW - D-Amino acids
KW - Diagnostic markers
UR - http://www.scopus.com/inward/record.url?scp=80052617957&partnerID=8YFLogxK
U2 - 10.1016/j.chroma.2011.07.087
DO - 10.1016/j.chroma.2011.07.087
M3 - Article
C2 - 21890145
AN - SCOPUS:80052617957
SN - 0021-9673
VL - 1218
SP - 7130
EP - 7136
JO - Journal of Chromatography A
JF - Journal of Chromatography A
IS - 40
ER -