TY - JOUR
T1 - A simple visual analog scale for pain is as responsive as the WOMAC, the SF-36, and the EQ-5D in measuring outcomes of revision hip arthroplasty
AU - Zampelis, Vasileios
AU - Ornstein, Ewald
AU - Franzen, Herbert
AU - Atroshi, Isam
PY - 2014
Y1 - 2014
N2 - Background and purpose - Little is known about the comparative performance of patient-reported outcome measures in revision hip arthroplasty. We compared the performance of the WOMAC, the SF-36, the EQ-5D, and a pain-related visual analog scale (VAS) in revision hip arthroplasty. Methods - 45 patients with aseptic prosthetic loosening following primary hip arthroplasty completed the WOMAC, the SF-36, the EQ-5D, and a VAS for pain-at baseline and 2 years after revision. Responsiveness of the measures was compared with the effect size (with >= 0.8 being considered large). Agreement between scales measuring the same type of outcome (pain or physical function) was assessed with the Bland-Altman method. Results - The mean preoperative scores for the pain and physical function scales of WOMAC and SF-36, EQ-5D index, and VAS for pain improved statistically significantly 2 years after revision. The effect size for the WOMAC pain was 1.7, that for SF-36 pain was 1.4, that for WOMAC physical function was 1.6, that for SF-36 physical function was 0.8, and that for EQ-5D index was 1.2. The VAS for pain had an effect size of 2.1, which was larger than that for SF-36 pain and for the EQ-5D index (p <= 0.03) but not for WOMAC pain (p = 0.2). The limits of agreement between WOMAC pain, SF-36 pain, and the VAS scale measuring pain- and between the WOMAC and SF-36 scales measuring physical function-were wide. Internal-consistency reliability was high for the WOMAC and SF-36 scales but low for the EQ-5D. Interpretation - In patients with first-time revision hip arthroplasty done for aseptic loosening, the WOMAC, SF-36, and EQ-5D showed high responsiveness in measuring patient-reported outcomes and the simple VAS for pain performed equally well.
AB - Background and purpose - Little is known about the comparative performance of patient-reported outcome measures in revision hip arthroplasty. We compared the performance of the WOMAC, the SF-36, the EQ-5D, and a pain-related visual analog scale (VAS) in revision hip arthroplasty. Methods - 45 patients with aseptic prosthetic loosening following primary hip arthroplasty completed the WOMAC, the SF-36, the EQ-5D, and a VAS for pain-at baseline and 2 years after revision. Responsiveness of the measures was compared with the effect size (with >= 0.8 being considered large). Agreement between scales measuring the same type of outcome (pain or physical function) was assessed with the Bland-Altman method. Results - The mean preoperative scores for the pain and physical function scales of WOMAC and SF-36, EQ-5D index, and VAS for pain improved statistically significantly 2 years after revision. The effect size for the WOMAC pain was 1.7, that for SF-36 pain was 1.4, that for WOMAC physical function was 1.6, that for SF-36 physical function was 0.8, and that for EQ-5D index was 1.2. The VAS for pain had an effect size of 2.1, which was larger than that for SF-36 pain and for the EQ-5D index (p <= 0.03) but not for WOMAC pain (p = 0.2). The limits of agreement between WOMAC pain, SF-36 pain, and the VAS scale measuring pain- and between the WOMAC and SF-36 scales measuring physical function-were wide. Internal-consistency reliability was high for the WOMAC and SF-36 scales but low for the EQ-5D. Interpretation - In patients with first-time revision hip arthroplasty done for aseptic loosening, the WOMAC, SF-36, and EQ-5D showed high responsiveness in measuring patient-reported outcomes and the simple VAS for pain performed equally well.
U2 - 10.3109/17453674.2014.887951
DO - 10.3109/17453674.2014.887951
M3 - Article
C2 - 24479622
SN - 1745-3682
VL - 85
SP - 128
EP - 132
JO - Acta Orthopaedica
JF - Acta Orthopaedica
IS - 2
ER -