T1 - Allergic contact dermatitis caused by dipropylene glycol diacrylate in the Omnipod® insulin pump
AU - Ulriksdotter, J.
AU - Svedman, C.
AU - Bruze, M.
AU - Mowitz, M.
N1 - Publisher Copyright:
© 2021 The Authors. British Journal of Dermatology published by John Wiley & Sons Ltd on behalf of British Association of Dermatologists
PY - 2022
Y1 - 2022
N2 - Background: Cases of allergic contact dermatitis (ACD) caused by isobornyl acrylate (IBOA) in the Omnipod® insulin pump have previously been reported. Objectives: To present three cases of patients with ACD caused by a new allergen in the pump, and results from chemical analyses. Methods: Omnipod pumps from different batches were analysed by gas chromatography–mass spectrometry. Aimed testing, with the department’s medical device (MD) series and substances identified in the pump including dipropylene glycol diacrylate (DPGDA) at 0·01% and 0·1% in petrolatum (pet.), was performed. Patch testing also included extracts from the device, the adhesive patch as is, and allergens from baseline series. Results: All patients tested positive to 0·1% DPGDA in pet., and two patients additionally to a 0·01% concentration. DPGDA was found in extracts of the Omnipod pumps brought by the patients. An Omnipod pump from an earlier batch contained tripropylene glycol diacrylate, IBOA, N,N-dimethylacrylamide, di(ethylene glycol)ethyl ether acrylate (DEGEA) but no DPGDA. One of the patients reacted positively to all of these allergens except DEGEA, which was not tested. Conclusions: When suspecting ACD to MDs, DPGDA at 0·1% in pet. should be tested. The contents of Omnipod have changed over time. Patch testing with updated test series and relevance assessment of positive reactions is a delicate task. Children, with lifelong use of MDs, risk contracting many allergies with potential cross-allergies. A question should be raised as to whether these low molecular weight acrylates should be used at all in devices constantly worn on the skin.
AB - Background: Cases of allergic contact dermatitis (ACD) caused by isobornyl acrylate (IBOA) in the Omnipod® insulin pump have previously been reported. Objectives: To present three cases of patients with ACD caused by a new allergen in the pump, and results from chemical analyses. Methods: Omnipod pumps from different batches were analysed by gas chromatography–mass spectrometry. Aimed testing, with the department’s medical device (MD) series and substances identified in the pump including dipropylene glycol diacrylate (DPGDA) at 0·01% and 0·1% in petrolatum (pet.), was performed. Patch testing also included extracts from the device, the adhesive patch as is, and allergens from baseline series. Results: All patients tested positive to 0·1% DPGDA in pet., and two patients additionally to a 0·01% concentration. DPGDA was found in extracts of the Omnipod pumps brought by the patients. An Omnipod pump from an earlier batch contained tripropylene glycol diacrylate, IBOA, N,N-dimethylacrylamide, di(ethylene glycol)ethyl ether acrylate (DEGEA) but no DPGDA. One of the patients reacted positively to all of these allergens except DEGEA, which was not tested. Conclusions: When suspecting ACD to MDs, DPGDA at 0·1% in pet. should be tested. The contents of Omnipod have changed over time. Patch testing with updated test series and relevance assessment of positive reactions is a delicate task. Children, with lifelong use of MDs, risk contracting many allergies with potential cross-allergies. A question should be raised as to whether these low molecular weight acrylates should be used at all in devices constantly worn on the skin.
U2 - 10.1111/bjd.20751
DO - 10.1111/bjd.20751
M3 - Article
C2 - 34510410
AN - SCOPUS:85118432711
SN - 0007-0963
VL - 186
SP - 334
EP - 340
JO - British Journal of Dermatology
JF - British Journal of Dermatology
IS - 2
ER -