TY - JOUR
T1 - Comparing the Clinical Utility and Diagnostic Performance of Cerebrospinal Fluid P-Tau181, P-Tau217 and P-Tau231 Assays
AU - Leuzy, Antoine
AU - Janelidze, Shorena
AU - Mattsson-Carlgren, Niklas
AU - Palmqvist, Sebastian
AU - Jacobs, Dirk
AU - Cicognola, Claudia
AU - Stomrud, Erik
AU - Vanmechelen, Eugeen
AU - Dage, Jeffrey L
AU - Hansson, Oskar
N1 - Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.
PY - 2021
Y1 - 2021
N2 - BACKGROUND AND OBJECTIVES: Phosphorylated tau (P-tau) in cerebrospinal fluid (CSF) is considered an important biomarker in Alzheimer's disease (AD) and has been incorporated in recent diagnostic criteria. Several variants exist, including P-tau at threonines 181 (P-tau181), 217 (P-tau217) and 231 (P-tau231). However, no studies have compared their diagnostic performance or association to amyloid-β (Aβ) and Tau positron emission tomography (PET). Understanding which P-tau variant to use remains an important yet answered question. We aimed to compare the diagnostic accuracy of P-tau181, P-tau217 and P-tau231 in CSF for AD and their association with Aβ and Tau-PET.METHODS: 629 subjects from the Swedish BioFINDER-2 study were included (cognitively unimpaired, n=334; Aβ-positive mild cognitive impairment, n=84; AD dementia, n=119; and non-AD disorders, n=92). In addition to P-tau181 and P-tau217 measured using assays with the same detector antibodies from Eli Lilly (P-tau181Lilly, P-tau217Lilly) and P-tau231, we also included P-tau181 measurements from two commonly used assays (Innotest and Elecsys).RESULTS: Though all P-tau variants increased across the AD continuum, P-tau217Lilly showed the greatest dynamic range (13-fold-increase vs 1.9-5.4-fold-increase for other P-tau variants for AD dementia vs non-AD). P-tau217Lilly showed stronger correlations with Aβ- and Tau-PET (P<0.0001). P-tau217Lilly exhibited higher accuracy than other P-tau variants for separating AD dementia from non-AD (AUC, 0.991vs 0.906-0.982, P<0.0001) and for identifying Aβ- (AUC, 0.951 vs 0.816-0.924, P<0.0001) and Tau-PET positivity (AUC, 0.957 vs 0.836-0.938, P<0.0001). Finally, P-tau181Lilly generally performed better than the other P-tau181 assays, (e.g., AD dementia vs non-AD, AUC, 0.976 vs 0.923, P<0.0001).DISCUSSION: CSF P-tau217Lilly seem to be more useful than other included P-tau assays in the work-up of AD. Varied results across P-tau181 assays also highlights the importance of anti-tau antibodies for biomarker performance.CLASSIFICATION OF EVIDENCE: This study provides class II evidence that phosphorylated tau at threonine 217 provides higher diagnostic accuracy for diagnosis of AD dementia than P-tau at threonine 181 or 231.
AB - BACKGROUND AND OBJECTIVES: Phosphorylated tau (P-tau) in cerebrospinal fluid (CSF) is considered an important biomarker in Alzheimer's disease (AD) and has been incorporated in recent diagnostic criteria. Several variants exist, including P-tau at threonines 181 (P-tau181), 217 (P-tau217) and 231 (P-tau231). However, no studies have compared their diagnostic performance or association to amyloid-β (Aβ) and Tau positron emission tomography (PET). Understanding which P-tau variant to use remains an important yet answered question. We aimed to compare the diagnostic accuracy of P-tau181, P-tau217 and P-tau231 in CSF for AD and their association with Aβ and Tau-PET.METHODS: 629 subjects from the Swedish BioFINDER-2 study were included (cognitively unimpaired, n=334; Aβ-positive mild cognitive impairment, n=84; AD dementia, n=119; and non-AD disorders, n=92). In addition to P-tau181 and P-tau217 measured using assays with the same detector antibodies from Eli Lilly (P-tau181Lilly, P-tau217Lilly) and P-tau231, we also included P-tau181 measurements from two commonly used assays (Innotest and Elecsys).RESULTS: Though all P-tau variants increased across the AD continuum, P-tau217Lilly showed the greatest dynamic range (13-fold-increase vs 1.9-5.4-fold-increase for other P-tau variants for AD dementia vs non-AD). P-tau217Lilly showed stronger correlations with Aβ- and Tau-PET (P<0.0001). P-tau217Lilly exhibited higher accuracy than other P-tau variants for separating AD dementia from non-AD (AUC, 0.991vs 0.906-0.982, P<0.0001) and for identifying Aβ- (AUC, 0.951 vs 0.816-0.924, P<0.0001) and Tau-PET positivity (AUC, 0.957 vs 0.836-0.938, P<0.0001). Finally, P-tau181Lilly generally performed better than the other P-tau181 assays, (e.g., AD dementia vs non-AD, AUC, 0.976 vs 0.923, P<0.0001).DISCUSSION: CSF P-tau217Lilly seem to be more useful than other included P-tau assays in the work-up of AD. Varied results across P-tau181 assays also highlights the importance of anti-tau antibodies for biomarker performance.CLASSIFICATION OF EVIDENCE: This study provides class II evidence that phosphorylated tau at threonine 217 provides higher diagnostic accuracy for diagnosis of AD dementia than P-tau at threonine 181 or 231.
U2 - 10.1212/WNL.0000000000012727
DO - 10.1212/WNL.0000000000012727
M3 - Article
C2 - 34493616
SN - 1526-632X
VL - 97
SP - e1681-e1694
JO - Neurology
JF - Neurology
IS - 17
ER -