T1 - Comparison of image quality in chest, hip and pelvis examinations between mobile equipment in nursing homes and static indirect radiography equipment in the hospital
AU - Precht, H.
AU - Hansen, D. L.
AU - Ring-Pedersen, B. M.
AU - Møller Hansen, L. F.
AU - Waaler, D.
AU - Tingberg, A.
AU - Midtgaard, M.
AU - Jensen Ohlsen, M. G.
AU - Juhl Hankelbjerg, S. T.
AU - Ravn, P.
AU - Jensen, I. E.
AU - Christensen, J. K.
AU - Blackburn Andersen, P. A.
PY - 2020/5/1
Y1 - 2020/5/1
N2 - Introduction: A hospital environment can be a significant burden and a health risk especially for dementia patients. Mobile x-ray equipment (ME) is used to enable imaging of these patients at home. The aim was to compare image quality (IQ) of chest, hip and pelvis images from ME to the stationary equipment (SE) used in a hospital department. Methods: We analysed examinations of the chest (n = 20), hip (n = 64) and pelvis (n = 32). Images were equally obtained from each setting of ME and SE. All images were graded using Visual Grading Analysis (VGA) by three radiographers (hip and pelvis) and three radiologists (chest). Technical IQ assessment was done by 80 additional images of a Contrast-Detail Radiography phantom (CDRAD). Results: All chest images were approved for diagnostic use, as well as the hip AP and pelvis images from SE. ‘Approved proportion of ME images was for HIP antero-posterior (AP) and pelvis, 78% [95% CI: 52–94%] and 81% [95% CI: 54–96%] respectively. Hip axial had an overall low, but not significant different approval rate. Ordered logistic regression indicated higher IQ of HIP AP and pelvic images from SE. This contrasts that the CDRAD substudy indicated better IQ, expressed as IQFinv, from ME. Conclusion: The VGA showed higher IQ for the SE system, while the CDRAD showed higher IQ for the ME system. Implications for practice: Dementia patients can be examined at their home if the acquisition is optimised according to image quality in conjunct to radiation dose. Performing imaging out of the hospital and coordinating the patients’ further treatment are new work areas for radiographers and requires excellent communication skills.
AB - Introduction: A hospital environment can be a significant burden and a health risk especially for dementia patients. Mobile x-ray equipment (ME) is used to enable imaging of these patients at home. The aim was to compare image quality (IQ) of chest, hip and pelvis images from ME to the stationary equipment (SE) used in a hospital department. Methods: We analysed examinations of the chest (n = 20), hip (n = 64) and pelvis (n = 32). Images were equally obtained from each setting of ME and SE. All images were graded using Visual Grading Analysis (VGA) by three radiographers (hip and pelvis) and three radiologists (chest). Technical IQ assessment was done by 80 additional images of a Contrast-Detail Radiography phantom (CDRAD). Results: All chest images were approved for diagnostic use, as well as the hip AP and pelvis images from SE. ‘Approved proportion of ME images was for HIP antero-posterior (AP) and pelvis, 78% [95% CI: 52–94%] and 81% [95% CI: 54–96%] respectively. Hip axial had an overall low, but not significant different approval rate. Ordered logistic regression indicated higher IQ of HIP AP and pelvic images from SE. This contrasts that the CDRAD substudy indicated better IQ, expressed as IQFinv, from ME. Conclusion: The VGA showed higher IQ for the SE system, while the CDRAD showed higher IQ for the ME system. Implications for practice: Dementia patients can be examined at their home if the acquisition is optimised according to image quality in conjunct to radiation dose. Performing imaging out of the hospital and coordinating the patients’ further treatment are new work areas for radiographers and requires excellent communication skills.
KW - Image quality
KW - Indirect digital radiography
KW - Mobile radiography
KW - Nursing homes
U2 - 10.1016/j.radi.2019.10.004
DO - 10.1016/j.radi.2019.10.004
M3 - Article
C2 - 32052778
AN - SCOPUS:85074496276
SN - 1078-8174
VL - 26
SP - 31
EP - 37
JO - Radiography
JF - Radiography
IS - 2
ER -