Comparison of two methods for evaluation of image quality of lumbar spine radiographs

Anders Tingberg, M. Båth, M. Håkansson, Joakim Medin, M. Sandborg, G. Alm-Carlsson, Sören Mattsson, L.G. Månsson

Research output: Chapter in Book/Report/Conference proceedingPaper in conference proceedingpeer-review

Abstract

Purpose To evaluate the image quality of clinical radiographs with two different methods, and to find correlations between the two methods. Methods Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. Results The VGA study showed that images with low noise are preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study the visibility of the lesions was independent of the spatial resolution and the noise level. Discussion In this study we found no correlation between the two methods, probably because the detectability of the artificial lesions was not influenced by the manipulations of noise level and resolution. Hence, the detection of lesions in lumbar spine radiography may not be a quantum-noise limited task. The results show the strength of the VGA technique in terms of detecting small changes in the two image quality parameters. The method is more robust and has a higher statistical power than the ROC related method and could therefore, in some cases, be more suitable for use in optimization studies.
Original languageEnglish
Title of host publicationProceedings of SPIE
PublisherSPIE
Pages251-262
Volume5372
ISBN (Print)0819452858
DOIs
Publication statusPublished - 2004
EventMedical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment - San Diego, CA, United States
Duration: 2004 Feb 17 → …

Publication series

Name
Volume5372
ISSN (Print)1996-756X
ISSN (Electronic)0277-786X

Conference

ConferenceMedical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment
Country/TerritoryUnited States
CitySan Diego, CA
Period2004/02/17 → …

Subject classification (UKÄ)

  • Radiology and Medical Imaging

Fingerprint

Dive into the research topics of 'Comparison of two methods for evaluation of image quality of lumbar spine radiographs'. Together they form a unique fingerprint.

Cite this