TY - JOUR
T1 - Competitive capacitive biosensing technique (CCBT): A novel technique for monitoring low molecular mass analytes using glucose assay as a model study.
AU - Labib, Mahmoud
AU - Hedström, Martin
AU - Amin, Magdy
AU - Mattiasson, Bo
PY - 2010
Y1 - 2010
N2 - A novel technique for monitoring of low molecular mass analytes using a flow-injection capacitive biosensor is presented. The method is based on the ability of a small molecular mass analyte to displace a large analyte-carrier conjugate from the binding sites of an immobilized biorecognition element with weak affinity to both compounds. A model study was performed on glucose as the small molecular mass analyte. In the absence of glucose, binding of a glucose polymer or a glycoconjugate to concanavalin A results in a capacitance decrease. Upon introduction of glucose, it displaces a part of the bound glucose polymer or glycoconjugate leading to a partial restoration of capacitance. Experimental results show that the change in capacitance depends linearly on glucose concentration within the range from 1.0 x 10(-5) to 1.0 x 10(-1) M, corresponding to 1.8 microg ml(-1) to 18 mg ml(-1) in a logarithmic plot, with a detection limit of 1.0 x 10(-6) (0.18 microg ml(-1)) under optimized conditions. In addition, by modifying the molecular mass of the glucose polymer, amount of biorecognition element, and buffer composition, we were able to tune the analyte-sensing range. The developed technique has the benefits of expanded dynamic range, high sensitivity, and excellent reusability.
AB - A novel technique for monitoring of low molecular mass analytes using a flow-injection capacitive biosensor is presented. The method is based on the ability of a small molecular mass analyte to displace a large analyte-carrier conjugate from the binding sites of an immobilized biorecognition element with weak affinity to both compounds. A model study was performed on glucose as the small molecular mass analyte. In the absence of glucose, binding of a glucose polymer or a glycoconjugate to concanavalin A results in a capacitance decrease. Upon introduction of glucose, it displaces a part of the bound glucose polymer or glycoconjugate leading to a partial restoration of capacitance. Experimental results show that the change in capacitance depends linearly on glucose concentration within the range from 1.0 x 10(-5) to 1.0 x 10(-1) M, corresponding to 1.8 microg ml(-1) to 18 mg ml(-1) in a logarithmic plot, with a detection limit of 1.0 x 10(-6) (0.18 microg ml(-1)) under optimized conditions. In addition, by modifying the molecular mass of the glucose polymer, amount of biorecognition element, and buffer composition, we were able to tune the analyte-sensing range. The developed technique has the benefits of expanded dynamic range, high sensitivity, and excellent reusability.
UR - https://www.scopus.com/pages/publications/77953477424
U2 - 10.1007/s00216-010-3641-8
DO - 10.1007/s00216-010-3641-8
M3 - Article
SN - 1618-2642
VL - 397
SP - 1217
EP - 1224
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
ER -