TY - JOUR
T1 - Development and characterization of the Portable Ice Nucleation Chamber 2 (PINCii)
AU - Castarède, Dimitri
AU - Brasseur, Zoé
AU - Wu, Yusheng
AU - Kanji, Zamin A.
AU - Hartmann, Markus
AU - Ahonen, Lauri
AU - Bilde, Merete
AU - Kulmala, Markku
AU - Petäjä, Tuukka
AU - Pettersson, Jan B.C.
AU - Sierau, Berko
AU - Stetzer, Olaf
AU - Stratmann, Frank
AU - Svenningsson, Birgitta
AU - Swietlicki, Erik
AU - Thu Nguyen, Quynh
AU - Duplissy, Jonathan
AU - Thomson, Erik S.
PY - 2023/8/23
Y1 - 2023/8/23
N2 - The Portable Ice Nucleation Chamber 2 (PINCii) is a newly developed continuous flow diffusion chamber (CFDC) for measuring ice nucleating particles (INPs). PINCii is a vertically oriented parallel-plate CFDC that has been engineered to improve upon the limitations of previous generations of CFDCs. This work presents a detailed description of the PINCii instrument and the upgrades that make it unique compared with other operational CFDCs. The PINCii design offers several possibilities for improved INP measurements. Notably, a specific icing procedure results in low background particle counts, which demonstrates the potential for PINCii to measure INPs at low concentrations (<10L-1). High-spatial-resolution wall-temperature mapping enables the identification of temperature inhomogeneities on the chamber walls. This feature is used to introduce and discuss a new method for analyzing CFDC data based on the most extreme lamina conditions present within the chamber, which represent conditions most likely to trigger ice nucleation. A temperature gradient can be maintained throughout the evaporation section in addition to the main chamber, which enables PINCii to be used to study droplet activation processes or to extend ice crystal growth. A series of both liquid droplet activation and ice nucleation experiments were conducted at temperature and saturation conditions that span the spectrum of PINCii's operational conditions (-50≤temperature≤-15°C and 100 ≤ relative humidity with respect to ice≤160%) to demonstrate the instrument's capabilities. In addition, typical sources of uncertainty in CFDCs, including particle background, particle loss, and variations in aerosol lamina temperature and relative humidity, are quantified and discussed for PINCii.
AB - The Portable Ice Nucleation Chamber 2 (PINCii) is a newly developed continuous flow diffusion chamber (CFDC) for measuring ice nucleating particles (INPs). PINCii is a vertically oriented parallel-plate CFDC that has been engineered to improve upon the limitations of previous generations of CFDCs. This work presents a detailed description of the PINCii instrument and the upgrades that make it unique compared with other operational CFDCs. The PINCii design offers several possibilities for improved INP measurements. Notably, a specific icing procedure results in low background particle counts, which demonstrates the potential for PINCii to measure INPs at low concentrations (<10L-1). High-spatial-resolution wall-temperature mapping enables the identification of temperature inhomogeneities on the chamber walls. This feature is used to introduce and discuss a new method for analyzing CFDC data based on the most extreme lamina conditions present within the chamber, which represent conditions most likely to trigger ice nucleation. A temperature gradient can be maintained throughout the evaporation section in addition to the main chamber, which enables PINCii to be used to study droplet activation processes or to extend ice crystal growth. A series of both liquid droplet activation and ice nucleation experiments were conducted at temperature and saturation conditions that span the spectrum of PINCii's operational conditions (-50≤temperature≤-15°C and 100 ≤ relative humidity with respect to ice≤160%) to demonstrate the instrument's capabilities. In addition, typical sources of uncertainty in CFDCs, including particle background, particle loss, and variations in aerosol lamina temperature and relative humidity, are quantified and discussed for PINCii.
U2 - 10.5194/amt-16-3881-2023
DO - 10.5194/amt-16-3881-2023
M3 - Article
AN - SCOPUS:85172927268
SN - 1867-1381
VL - 16
SP - 3881
EP - 3899
JO - Atmospheric Measurement Techniques
JF - Atmospheric Measurement Techniques
IS - 16
ER -