TY - JOUR
T1 - Extracorporeal immunoadsorption from whole blood based on the avidin-biotin concept. Evaluation of a new method
AU - Garkavij, Michael
AU - Tennvall, Jan
AU - Strand, Sven-Erik
AU - Nilsson, Rune
AU - Lindgren, Lars
AU - Chen, Jangin
AU - Isaksson, Martin
AU - Eriksson, Håkan
AU - Sjögren, Hans-Olof
PY - 1996
Y1 - 1996
N2 - This study of 36 rats with rat colon adenocarcinoma transplants was carried out to investigate the efficacy of a new method of whole blood immunoadsorption (WBIA) in removing biotinylated monoclonal antibodies (MAbs) directly from unseparated blood, in order to increase 'the tumor/normal-tissue uptake ratio', as compared with extracorporeal immunoadsorption (ECIA) of antibodies from plasma. Compared with the ECIA system, the overall volume of the WBIA system (comprising only a pump, an adsorption column, a drop-chamber and tubings) was less (3.6 vs. 6.2 ml), and procedure duration 2 h less. The 17 rats undergoing the WBIA procedure, started 12 h after i.v. injection of 4.0-4.5 MBq 125I-BR96-biotin, manifested neither hemolysis nor any other complication; no signs of organ edema were found at dissection; whole body and blood radioactivity values were reduced by 51% and 89.5%, respectively. The WBIA method was as effective as ECIA, but technically simpler, safer and more reliable.
AB - This study of 36 rats with rat colon adenocarcinoma transplants was carried out to investigate the efficacy of a new method of whole blood immunoadsorption (WBIA) in removing biotinylated monoclonal antibodies (MAbs) directly from unseparated blood, in order to increase 'the tumor/normal-tissue uptake ratio', as compared with extracorporeal immunoadsorption (ECIA) of antibodies from plasma. Compared with the ECIA system, the overall volume of the WBIA system (comprising only a pump, an adsorption column, a drop-chamber and tubings) was less (3.6 vs. 6.2 ml), and procedure duration 2 h less. The 17 rats undergoing the WBIA procedure, started 12 h after i.v. injection of 4.0-4.5 MBq 125I-BR96-biotin, manifested neither hemolysis nor any other complication; no signs of organ edema were found at dissection; whole body and blood radioactivity values were reduced by 51% and 89.5%, respectively. The WBIA method was as effective as ECIA, but technically simpler, safer and more reliable.
U2 - 10.3109/02841869609101646
DO - 10.3109/02841869609101646
M3 - Article
SN - 1651-226X
VL - 35
SP - 309
EP - 312
JO - Acta Oncologica
JF - Acta Oncologica
IS - 3
ER -