TY - JOUR
T1 - Hemodynamic effects of vacuum-assisted closure therapy in cardiac surgery: assessment using magnetic resonance imaging.
AU - Petzina, Rainer
AU - Ugander, Martin
AU - Gustafsson, Lotta
AU - Engblom, Henrik
AU - Sjögren, Johan
AU - Hetzer, Roland
AU - Ingemansson, Richard
AU - Arheden, Håkan
AU - Malmsjö, Malin
PY - 2007
Y1 - 2007
N2 - Objective: The hemodynamic effects of vacuum-assisted closure therapy in cardiac surgery are debated. The aim of the present study was to quantify cardiac output and left ventricular chamber volumes after vacuum-assisted closure using magnetic resonance imaging, which is known to be the most accurate method for quantifying these measures. Methods: Six pigs had median sternotomy followed by vacuum-assisted closure treatment in the presence and absence of a paraffin gauze interface dressing. Cardiac output and stroke volume were examined using magnetic resonance imaging flow quantification (breath-hold and real-time). Chamber volumes were assessed using cine magnetic resonance imaging. Results: Cardiac output and stroke volume decreased immediately after application of negative pressures of 75, 125, and 175 mm Hg (13% +/- 1% decrease in cardiac output). Interposition of 4 layers of paraffin gauze dressing over the heart during vacuum-assisted closure therapy resulted in a smaller decrease in cardiac output (8% +/- 1%). Conclusions: Vacuum-assisted closure therapy results in an immediate decrease in cardiac output, although to a lesser extent than shown previously. Covering the heart with a wound interface dressing lessens the hemodynamic effects of vacuum-assisted closure.
AB - Objective: The hemodynamic effects of vacuum-assisted closure therapy in cardiac surgery are debated. The aim of the present study was to quantify cardiac output and left ventricular chamber volumes after vacuum-assisted closure using magnetic resonance imaging, which is known to be the most accurate method for quantifying these measures. Methods: Six pigs had median sternotomy followed by vacuum-assisted closure treatment in the presence and absence of a paraffin gauze interface dressing. Cardiac output and stroke volume were examined using magnetic resonance imaging flow quantification (breath-hold and real-time). Chamber volumes were assessed using cine magnetic resonance imaging. Results: Cardiac output and stroke volume decreased immediately after application of negative pressures of 75, 125, and 175 mm Hg (13% +/- 1% decrease in cardiac output). Interposition of 4 layers of paraffin gauze dressing over the heart during vacuum-assisted closure therapy resulted in a smaller decrease in cardiac output (8% +/- 1%). Conclusions: Vacuum-assisted closure therapy results in an immediate decrease in cardiac output, although to a lesser extent than shown previously. Covering the heart with a wound interface dressing lessens the hemodynamic effects of vacuum-assisted closure.
U2 - 10.1016/j.jtcvs.2007.01.011
DO - 10.1016/j.jtcvs.2007.01.011
M3 - Article
SN - 1097-685X
VL - 133
SP - 1154
EP - 1162
JO - Journal of Thoracic and Cardiovascular Surgery
JF - Journal of Thoracic and Cardiovascular Surgery
IS - 5
ER -