T1 - Indications, Detection, Completion and Retention Rates of Capsule Endoscopy in Two Decades of Use
T2 - A Systematic Review and Meta-Analysis
AU - Valdivia, Pablo Cortegoso
AU - Skonieczna-żydecka, Karolina
AU - Elosua, Alfonso
AU - Sciberras, Martina
AU - Piccirelli, Stefania
AU - Rullan, Maria
AU - Tabone, Trevor
AU - Gawel, Katarzyna
AU - Stachowski, Adam
AU - Lemiński, Artur
AU - Marlicz, Wojciech
AU - Fernández-Urién, Ignacio
AU - Ellul, Pierre
AU - Spada, Cristiano
AU - Pennazio, Marco
AU - Toth, Ervin
AU - Koulaouzidis, Anastasios
PY - 2022/5
Y1 - 2022/5
N2 - Background: Capsule endoscopy (CE) has become a widespread modality for non-invasive evaluation of the gastrointestinal (GI) tract, with several CE models having been developed throughout the years. The aim of this systematic review and meta-analysis is to evaluate performance measures such as completion, detection and retention rates of CE. Methods: Literature through to August 2021 was screened for articles regarding all capsule types: small bowel, double-headed capsule for the colon or PillCam® Crohn’s capsule, magnetically-controlled capsule endoscopy, esophageal capsule and patency capsule. Primary outcomes included detection rate (DR), completion rate (CR) and capsule retention rate (RR). DR, CR and RR were also analyzed in relation to indications such as obscure GI bleeding (OGIB), known/suspected Crohn’s disease (CD), celiac disease (CeD), neoplastic lesions (NL) and clinical symptoms (CS). Results: 328 original articles involving 86,930 patients who underwent CE were included. OGIB was the most common indication (n = 44,750), followed by CS (n = 17,897), CD (n = 11,299), NL (n = 4989) and CeD (n = 947). The most used capsule type was small bowel CE in 236 studies. DR, CR and RR for all indications were 59%, 89.6% and 2%, respectively. According to specific indications: DR were 55%, 66%, 63%, 52% and 62%; CR were 90.6%, 86.5%, 78.2%, 94% and 92.8%; and RR were 2%, 4%, 1%, 6% and 2%. Conclusions: Pooled DR, CR and RR are acceptable for all capsule types. OGIB is the most common indication for CE. Technological advancements have expanded the scope of CE devices in detecting GI pathology with acceptable rates for a complete examination.
AB - Background: Capsule endoscopy (CE) has become a widespread modality for non-invasive evaluation of the gastrointestinal (GI) tract, with several CE models having been developed throughout the years. The aim of this systematic review and meta-analysis is to evaluate performance measures such as completion, detection and retention rates of CE. Methods: Literature through to August 2021 was screened for articles regarding all capsule types: small bowel, double-headed capsule for the colon or PillCam® Crohn’s capsule, magnetically-controlled capsule endoscopy, esophageal capsule and patency capsule. Primary outcomes included detection rate (DR), completion rate (CR) and capsule retention rate (RR). DR, CR and RR were also analyzed in relation to indications such as obscure GI bleeding (OGIB), known/suspected Crohn’s disease (CD), celiac disease (CeD), neoplastic lesions (NL) and clinical symptoms (CS). Results: 328 original articles involving 86,930 patients who underwent CE were included. OGIB was the most common indication (n = 44,750), followed by CS (n = 17,897), CD (n = 11,299), NL (n = 4989) and CeD (n = 947). The most used capsule type was small bowel CE in 236 studies. DR, CR and RR for all indications were 59%, 89.6% and 2%, respectively. According to specific indications: DR were 55%, 66%, 63%, 52% and 62%; CR were 90.6%, 86.5%, 78.2%, 94% and 92.8%; and RR were 2%, 4%, 1%, 6% and 2%. Conclusions: Pooled DR, CR and RR are acceptable for all capsule types. OGIB is the most common indication for CE. Technological advancements have expanded the scope of CE devices in detecting GI pathology with acceptable rates for a complete examination.
KW - capsule endoscopy
KW - completion
KW - detection
KW - indications
KW - systematic review
U2 - 10.3390/diagnostics12051105
DO - 10.3390/diagnostics12051105
M3 - Review article
C2 - 35626261
AN - SCOPUS:85129737069
SN - 2075-4418
VL - 12
JO - Diagnostics
JF - Diagnostics
IS - 5
M1 - 1105
ER -