Skip to main navigation Skip to search Skip to main content

Indoor air levels of polycyclic aromatic compounds (PAC) in public buildings with creosote impregnated constructions – A pilot case study using passive samplers

  • Region Skåne

Research output: Contribution to journal › Article › peer-review

Abstract

Creosote has been used in Sweden as a wood preservative in buildings since the 19th century. These buildings can function as workplaces, homes, and cultural buildings to which the public has access. Creosote contains polycyclic aromatic hydrocarbons (PAH) which are well known carcinogens. To understand exposure and risks in an indoor environment, it is important to determine air levels of parent PAHs as well as the more toxic nitrated and oxygenated PAH derivatives (NPAH, OPAH). This study aims to investigate indoor air levels of polycyclic aromatic compounds (PACs) e.g., PAH, NPAH, OPAH and dibenzothiophenes in buildings containing creosote sources and whether these levels pose a health risk. Four cultural buildings were studied, all located within a radius of 130 m. Two were known to have creosote sources, and two had not. Polyurethane foam passive air samplers (PUF-PAS) were used to indicate possible point sources. PUF-PAS measurements were performed for one month in each building winter and summer. Simultaneously, PAC outdoor level measurements were performed. Buildings with creosote impregnated constructions had notably higher indoor air levels of PAC (31–1200 ng m−3) compared to the two buildings without creosote sources (14–45 ng m−3). The PAH cancer potency (sum of benzo[a]pyrene equivalents (BaPeq)) was more than one order of magnitude higher in the buildings containing creosote impregnated wood compared to reference buildings. The highest value was 5.1 BaPeq ng m−3 which was significantly higher than the outdoor winter measurement (1.3 BaPeq ng m−3). Fluoranthene and phenanthrene, with significant distribution in gas phase, but also several particulate NPAHs contributed significantly to the total cancer risk. Thus, creosote containing buildings can still contaminate the indoor air with PACs despite being over a hundred years old. The PUF-PAS was shown to be a good tool providing quantitative/semiquantitative measures of PACs exposure in indoor microenvironments.

Original languageEnglish
Article number141240
JournalChemosphere
Volume352
DOIs
Publication statusPublished - 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Subject classification (UKÄ)

  • Occupational Health and Environmental Health

Free keywords

  • Creosote
  • Indoor air
  • PAH derivatives
  • PAHs
  • Passive samplers
  • Risk assessment

Fingerprint

Dive into the research topics of 'Indoor air levels of polycyclic aromatic compounds (PAC) in public buildings with creosote impregnated constructions – A pilot case study using passive samplers'. Together they form a unique fingerprint.

Cite this