Influence of environment on tunneling thermometry

Tommy Holmqvist, Jukka P. Pekola, Matthias Meschke

Research output: Contribution to journalArticlepeer-review

2 Citations (SciVal)

Abstract

The electromagnetic environment of a tunnel junction can influence significantly the tunneling characteristics. We investigate experimentally a particular environment formed by tunnel junctions and compare the results with a theoretical model. We discuss Single Junction Thermometer and a two junction Coulomb Blockade Thermometer as examples.

Original languageEnglish
Pages (from-to)172-178
Number of pages7
JournalJournal of Low Temperature Physics
Volume154
Issue number5-6
DOIs
Publication statusPublished - 2009
Externally publishedYes

Keywords

  • Electromagnetic environment
  • Thermometry
  • Tunnel junctions