TY - JOUR
T1 - International quality assurance study for characterization of Streptococcus pyogenes
AU - Neal, Shona
AU - Beall, Bernard
AU - Ekelund, Kim
AU - Henriques-Normark, Birgitta
AU - Jasir, Aftab
AU - Johnson, Dwight
AU - Kaplan, Edward
AU - Lovgren, Marguerite
AU - Reinert, Ralf Rene
AU - Efstratiou, Androulla
PY - 2007
Y1 - 2007
N2 - Surveillance of group A streptococcal (GAS) infections was undertaken as a major component of the European Commission-funded project on severe GAS disease in Europe (strep-EURO). One aim of strep-EURO was to improve the quality of GAS characterization by standardization of methods. An external quality assurance study (EQA) was therefore carried out to evaluate current global performance. Eleven strep-EURO and seven other streptococcal reference centers received a panel of 20 coded GAS isolates for typing. Conventional phenotypic typing (based on cell surface T and M protein antigens and opacity factor [OF] production) and molecular methods (emm gene typing) were used either as single or combined approaches to GAS typing. T typing was performed by 16 centers; 12 centers found one or more of the 20 strains nontypeable (typeability, 89%), and 11 centers reported at least one incorrect result (concordance, 93%). The 10 centers that tested for OF production achieved 96% concordance. Limited availability of antisera resulted in poor typeability values from the four centers that performed phenotypic M typing (41%), three of which also performed anti-OF typing (typeability, 63%); however, concordance was high for both M (100%) and anti-OF (94%) typing. In contrast, the 15 centers that performed emm gene sequencing achieved excellent typeability (97%) and concordance (98%), although comparison of the performance between centers yielded typeability rates from 65 to 100% and concordance values from 83 to 100%. With the rapid expansion and use of molecular genotypic methods to characterize GAS, continuation of EQA is essential in order to achieve international standardization and comparison of type distributions.
AB - Surveillance of group A streptococcal (GAS) infections was undertaken as a major component of the European Commission-funded project on severe GAS disease in Europe (strep-EURO). One aim of strep-EURO was to improve the quality of GAS characterization by standardization of methods. An external quality assurance study (EQA) was therefore carried out to evaluate current global performance. Eleven strep-EURO and seven other streptococcal reference centers received a panel of 20 coded GAS isolates for typing. Conventional phenotypic typing (based on cell surface T and M protein antigens and opacity factor [OF] production) and molecular methods (emm gene typing) were used either as single or combined approaches to GAS typing. T typing was performed by 16 centers; 12 centers found one or more of the 20 strains nontypeable (typeability, 89%), and 11 centers reported at least one incorrect result (concordance, 93%). The 10 centers that tested for OF production achieved 96% concordance. Limited availability of antisera resulted in poor typeability values from the four centers that performed phenotypic M typing (41%), three of which also performed anti-OF typing (typeability, 63%); however, concordance was high for both M (100%) and anti-OF (94%) typing. In contrast, the 15 centers that performed emm gene sequencing achieved excellent typeability (97%) and concordance (98%), although comparison of the performance between centers yielded typeability rates from 65 to 100% and concordance values from 83 to 100%. With the rapid expansion and use of molecular genotypic methods to characterize GAS, continuation of EQA is essential in order to achieve international standardization and comparison of type distributions.
U2 - 10.1128/JCM.02146-06
DO - 10.1128/JCM.02146-06
M3 - Article
C2 - 17267628
SN - 1098-660X
VL - 45
SP - 1175
EP - 1179
JO - Journal of Clinical Microbiology
JF - Journal of Clinical Microbiology
IS - 4
ER -