Investigation and analysis of ferrous sulfate polyvinyl alcohol (PVA) gel dosimeter

Brendan Hill, Sven Bäck, Martin Lepage, John Simpson, Brendan Healy, Clive Baldock

Research output: Contribution to journalArticlepeer-review

Abstract

Ferrous sulfate (Fe(SO4)2) PVA gels were investigated for a range of absorbed doses up to 20 Gy using both magnetic resonance imaging (MRI) and spectrophotometry to determine R1 and optical density (OD) dose responses and G values. It was found that R1- and OD-dose sensitivities increased with O2 saturation or by the introduction of a freeze-thaw cycle during preparation of the PVA gel. The storage temperature of the Fe(SO4)2 PVA gel at -18 degrees C increased R1-dose sensitivity above that of gels stored at 5 degrees C. The addition of sucrose to the formulation was found to result in the largest increase in both R1- and OD-dose sensitivities. Fe(SO4)2 PVA gel with and without the addition of xylenol orange was demonstrated to have a G value of approximately 20 ions/100 eV and with sucrose approximately 24 ions/100 eV.
Original languageEnglish
Pages (from-to)4233-4246
JournalPhysics in Medicine and Biology
Volume47
Issue number23
DOIs
Publication statusPublished - 2002

Subject classification (UKÄ)

  • Radiology and Medical Imaging

Fingerprint

Dive into the research topics of 'Investigation and analysis of ferrous sulfate polyvinyl alcohol (PVA) gel dosimeter'. Together they form a unique fingerprint.

Cite this