Is aqueductal stroke volume, measured with cine phase-contrast magnetic resonance imaging scans useful in predicting outcome of shunt surgery in suspected normal pressure hydrocephalus?

Babar Kahlon, Mårten Annertz, Freddy Ståhlberg, Stig Rehncrona

Research output: Contribution to journalArticlepeer-review

Abstract

OBJECTIVE: To evaluate clinical usefulness of cerebrospinal fluid stroke volume (SV) assessed in the cerebral aqueduct, via cine phase-contrast magnetic resonance imaging, for predicting outcome after shunt surgery in suspected normal pressure hydrocephalus. METHODS: Thirty-eight patients with suspected normal pressure hydrocephalus were included. SV was assessed using cine phase-contrast magnetic resonance imaging, and kept blinded until postoperative follow-up after 7 +/- 5.8 months (mean the results were standard deviation). Selection to surgery was based on a positive lumbar infusion test or cerebrospinal fluid tap test, and outcome was evaluated with objective tests. RESULTS: Six patients were excluded from SV measurements because of technical difficulties. Eight patients were not operated (negative lumbar infusion test and cerebrospinal fluid tap test). SV in the not operated patients (mean, 66 +/- 53 mu l) did not differ from the operated patients (95 +/- 78 mu l; P = 0.335). Operated patients showed statistically significant improvements in walk (P = 0.020), reaction time (P = 0.006), and memory (P = 0.001) tests. Patients were divided into three groups according to SV range: low (0-50 mu l), middle (51 - 100 mu l), and high (> 100 mu l). No statistically significant (P > 0.05) improvements in any of the objective tests were found in any of the SV the different SV ranges. The numbers of individually improved patients were similar in ranges: six out of seven in the low, nine out of nine in the middle, and five out of eight in the high range. Weak correlations were found between SV and the initial pulse,amplitude (R-s = 0.043; P = 0.014) as well as the plateau pulse amplitude (R-s = 0.043; P = 4) as measured with the lumbar infusion test. CONCLUSION: The data from this Study show no evidence that cine phase-contrast magnetic resonance imaging measurements of SV in the cerebral aqueduct are useful for selecting patients with normal pressure hydrocephalus symptoms to shunt surgery.
Original languageEnglish
Pages (from-to)124-129
JournalNeurosurgery
Volume60
Issue number1
DOIs
Publication statusPublished - 2007

Subject classification (UKÄ)

  • Surgery
  • Neurology

Fingerprint

Dive into the research topics of 'Is aqueductal stroke volume, measured with cine phase-contrast magnetic resonance imaging scans useful in predicting outcome of shunt surgery in suspected normal pressure hydrocephalus?'. Together they form a unique fingerprint.

Cite this