TY - JOUR
T1 - Modelling of OGTT curve identifies 1 h plasma glucose level as a strong predictor of incident type 2 diabetes: results from two prospective cohorts
AU - Alyass, Akram
AU - Almgren, Peter
AU - Åkerlund, Mikael
AU - Dushoff, Jonathan
AU - Isomaa, Bo
AU - Nilsson, Peter
AU - Tuomi, Tiinamaija
AU - Lyssenko, Valeriya
AU - Groop, Leif
AU - Meyre, David
PY - 2015
Y1 - 2015
N2 - Aims/hypothesis The relevance of the OGTT in predicting type 2 diabetes is unclear. We assessed the performance of 14 OGTT glucose traits in type 2 diabetes prediction. Methods We studied 2,603 and 2,386 Europeans from the Botnia study and Malmo Prevention Project (MPP) cohorts with baseline OGTT data. Over a follow-up period of 4.94 years and 23.5 years, 155 (5.95%) and 467 (19.57%) participants, respectively, developed type 2 diabetes. The main outcome was incident type 2 diabetes. Results One-hour plasma glucose (1h-PG) was a fair/good predictor of incident type 2 diabetes in the Botnia study and MPP (AUC for receiver operating characteristic [AUC(ROC)] 0.80 [0.77, 0.84] and 0.70 [0.68, 0.73]). 1h-PG alone outperformed the prediction model of multiple clinical risk factors (age, sex, BMI, family history of type 2 diabetes) in the Botnia study and MPP (AUC(ROC) 0.75 [0.72, 0.79] and 0.67 [0.64, 0.70]). The same clinical risk factors added to 1h-PG modestly increased prediction for incident type 2 diabetes (Botnia, AUC(ROC) 0.83 [0.80, 0.86]; MPP, AUC(ROC) 0.74 [0.72, 0.77]). 1h-PG also outperformed HbA(1c) in predicting type 2 diabetes in the Botnia cohort. A 1h-PG value of 8.9 mmol/l and 8.4 mmol/l was the optimal cut-point for initial screening and selection of high-risk individuals in the Botnia study and MPP, respectively, and represented 30% and 37% of all participants in these cohorts. High-risk individuals had a substantially increased risk of incident type 2 diabetes (OR 8.0 [5.5, 11.6] and 3.8 [3.1, 4.7]) and captured 75% and 62% of all incident type 2 diabetes in the Botnia study and MPP. Conclusions/interpretation1h-PG is a valuable prediction tool for identifying adults at risk for future type 2 diabetes.
AB - Aims/hypothesis The relevance of the OGTT in predicting type 2 diabetes is unclear. We assessed the performance of 14 OGTT glucose traits in type 2 diabetes prediction. Methods We studied 2,603 and 2,386 Europeans from the Botnia study and Malmo Prevention Project (MPP) cohorts with baseline OGTT data. Over a follow-up period of 4.94 years and 23.5 years, 155 (5.95%) and 467 (19.57%) participants, respectively, developed type 2 diabetes. The main outcome was incident type 2 diabetes. Results One-hour plasma glucose (1h-PG) was a fair/good predictor of incident type 2 diabetes in the Botnia study and MPP (AUC for receiver operating characteristic [AUC(ROC)] 0.80 [0.77, 0.84] and 0.70 [0.68, 0.73]). 1h-PG alone outperformed the prediction model of multiple clinical risk factors (age, sex, BMI, family history of type 2 diabetes) in the Botnia study and MPP (AUC(ROC) 0.75 [0.72, 0.79] and 0.67 [0.64, 0.70]). The same clinical risk factors added to 1h-PG modestly increased prediction for incident type 2 diabetes (Botnia, AUC(ROC) 0.83 [0.80, 0.86]; MPP, AUC(ROC) 0.74 [0.72, 0.77]). 1h-PG also outperformed HbA(1c) in predicting type 2 diabetes in the Botnia cohort. A 1h-PG value of 8.9 mmol/l and 8.4 mmol/l was the optimal cut-point for initial screening and selection of high-risk individuals in the Botnia study and MPP, respectively, and represented 30% and 37% of all participants in these cohorts. High-risk individuals had a substantially increased risk of incident type 2 diabetes (OR 8.0 [5.5, 11.6] and 3.8 [3.1, 4.7]) and captured 75% and 62% of all incident type 2 diabetes in the Botnia study and MPP. Conclusions/interpretation1h-PG is a valuable prediction tool for identifying adults at risk for future type 2 diabetes.
KW - Incident type 2 diabetes
KW - Mathematical modelling
KW - One-hour post-OGTT
KW - plasma glucose
KW - Oral glucose tolerance test
KW - Prevention
U2 - 10.1007/s00125-014-3390-x
DO - 10.1007/s00125-014-3390-x
M3 - Article
C2 - 25292440
SN - 1432-0428
VL - 58
SP - 87
EP - 97
JO - Diabetologia
JF - Diabetologia
IS - 1
ER -