Monte Carlo simulation of breast tomosynthesis: visibility of microcalcifications at different acquisition schemes

Research output: Chapter in Book/Report/Conference proceedingPaper in conference proceedingpeer-review

Abstract

Microcalcifications are one feature of interest in mammography and breast tomosynthesis (BT). To achieve optimal conditions for detection of microcalcifications in BT imaging, different acquisition geometries should be evaluated. The purpose of this work was to investigate the influence of acquisition schemes with different angular ranges, projection distributions and dose distributions on the visibility of microcalcifications in reconstructed BT volumes. Microcalcifications were inserted randomly in a high resolution software phantom and a simulation procedure was used to model a MAMMOMAT Inspiration BT system. The simulation procedure was based on analytical ray tracing to produce primary images, Monte Carlo to simulate scatter contributions and flatfield image acquisitions to model system characteristics. Image volumes were reconstructed using the novel method super-resolution reconstruction with statistical artifact reduction (SRSAR). For comparison purposes, the volume of the standard acquisition scheme (50 degrees angular range and uniform projection and dose distribution) was also reconstructed using standard filtered backprojection (FBP). To compare the visibility and depth resolution of the microcalcifications, signal difference to noise ratio (SDNR) and artifact spread function width (ASFW) were calculated. The acquisition schemes with very high central dose yielded significantly lower SDNR than the schemes with more uniform dose distributions. The ASFW was found to decrease (meaning an increase in depth resolution) with wider angular range. In conclusion, none of the evaluated acquisition schemes were found to yield higher SDNR or depth resolution for the simulated microcalcifications than the standard acquisition scheme.
Original languageEnglish
Title of host publicationMedical Imaging 2015: Physics of Medical Imaging
PublisherSPIE
Pages94121H
Volume9412
DOIs
Publication statusPublished - 2015
EventConference on Medical Imaging - Physics of Medical Imaging, 2015 - Orlando, FL, United States
Duration: 2015 Feb 222015 Feb 25

Publication series

Name
Volume9412
ISSN (Print)1996-756X
ISSN (Electronic)0277-786X

Conference

ConferenceConference on Medical Imaging - Physics of Medical Imaging, 2015
Country/TerritoryUnited States
CityOrlando, FL
Period2015/02/222015/02/25

Subject classification (UKÄ)

  • Radiology, Nuclear Medicine and Medical Imaging

Free keywords

  • breast tomosynthesis
  • Monte Carlo simulation
  • acquisition parameters
  • software breast phantom
  • microcalcification simulation