Multipoint temperature and oxygen-concentration measurements using rotational coherent anti-Stokes Raman spectroscopy

Research output: Contribution to journalArticlepeer-review

Abstract

A novel technique for coherent anti-Stokes Raman spectroscopy (CARS) measurements in multiple points is presented. With a system of cylindrical lenses, each laser beam is split into several focused beams, yielding separate planar boxcars configurations. Spectrally resolved CARS signals are detected at different heights on the CCD chip. With dual-broadband rotational CARS the setup is demonstrated for quantitative measurements of temperature- and oxygen-concentration profiles. The technique was demonstrated for three points only, but it can be extended to more points by use of special optics; this choice must be based on a sufficient signal-to-noise ratio in all points for the actual measurement condition.

Original languageEnglish
Pages (from-to)1535-1537
Number of pages3
JournalOptics Letters
Volume25
Issue number20
Publication statusPublished - 2000 Oct 15

Subject classification (UKÄ)

  • Atom and Molecular Physics and Optics