Numerical simulation of fluid flow in a monolithic exchanger related to high temperature and high pressure operating conditions

Faruk Selimovic, Bengt Sundén

Research output: Chapter in Book/Report/Conference proceedingPaper in conference proceedingpeer-review

Abstract

The purpose of this work is the enhancement of performance by a new design of monolithic heat exchangers under steady-state operating conditions.
Heat transfer phenomena and hydrodynamics have been studied and visualized by computational fluid dynamics (CFD).
Further, a simple gas distribution system has been analyzed in purpose to find the best performance of the exchanger.
To achieve this, 3D simulations of air flow were performed.
One of characteristics of monolithic structures is the low pressure drop and high heat transfer coefficient.
This is because they operate in the laminar flow regime and have high compactness.
However, some experimental studies show that when two fluids are introduced into monolith channels, the manifolds cause severe pressure losses.
Therefore, in this work, turbulent flow regime at low Reynolds numbers has been investigated to find the difference and better understanding of these structures, which are of interest in high temperature applications today.
The simulation shows that the pressure drop of the gas flow distributor is a key parameter affecting the heat transfer in the exchanger channels.
Original languageEnglish
Title of host publicationAdvanced Computational Methods and Experiments in Heat Transfer X
EditorsBengt Sunden, C. Brebbia
PublisherWIT Press
Pages25-35
Volume61
ISBN (Print)978-1-84564-122-1
DOIs
Publication statusPublished - 2008

Publication series

Name
Volume61

Subject classification (UKÄ)

  • Energy Engineering

Free keywords

  • high temperature heat exchangers
  • gas flow maldistribution
  • monolithic
  • heat exchangers
  • computational fluid dynamics

Fingerprint

Dive into the research topics of 'Numerical simulation of fluid flow in a monolithic exchanger related to high temperature and high pressure operating conditions'. Together they form a unique fingerprint.

Cite this