Optimal Epinephrine Concentration and Time Delay to Minimize Perfusion in Eyelid Surgery: Measured by Laser-Based Methods and a Novel Form of Extended-Wavelength Diffuse Reflectance Spectroscopy

Rafi Sheikh, Ulf Dahlstrand, Khashayar Memarzadeh, Jonas Blohmé, Nina Reistad, Malin Malmsjö

Research output: Contribution to journalArticlepeer-review

Abstract

OBJECTIVE:: This study investigates the hypoperfusion effects of epinephrine in local anesthesia in eyelid surgery. A novel form of extended-wavelength diffuse reflectance spectroscopy was evaluated. METHODS:: Blood perfusion in porcine eyelid flaps was measured using laser Doppler velocimetry and laser speckle contrast imaging, whereas the tissue response was measured using diffuse reflectance spectroscopy with a broad spectrum (450–1550 nm). Epinephrine was either injected cumulatively, 0.1 (1:10,000,000), 1.0 (1:1,000,000), 10 (1:100 000), and 100 μg/ml (1:10 000), to determine the dose–response relation, or given as a single dose (10 μg/ml). Control experiments were performed with saline or lidocaine. RESULTS:: Increasing concentrations of epinephrine resulted in a gradual decrease in tissue perfusion, measured by laser Doppler velocimetry and laser speckle contrast imaging, approaching a minimum after the injection of 10 μg/ml. Similar tissue response was observed with diffuse reflectance spectroscopy. The time from the injection of epinephrine (10 μg/ml) to the stabilization of hypoperfusion was 75 seconds. After administration of 10 μg/ml epinephrine, about 20% of the blood perfusion remained, supporting the use of epinephrine in eyelid flaps with a narrow pedicle. CONCLUSIONS:: 10 μg/ml epinephrine appears to be adequate for vasoconstriction before oculoplastic surgery. Incisions need only be delayed for about 1 minute. Extended-wavelength diffuse reflectance spectroscopy appears to be a promising technique for monitoring the tissue response following changes in blood perfusion in plastic surgery reconstructions. However, more rigorous validation of the technique is required before it can be implemented in clinical practice.

Original languageEnglish
Pages (from-to)123-129
JournalOphthalmic Plastic and Reconstructive Surgery
Volume34
Issue number2
Early online date2017 Feb 17
DOIs
Publication statusPublished - 2018

Subject classification (UKÄ)

  • Ophthalmology

Fingerprint

Dive into the research topics of 'Optimal Epinephrine Concentration and Time Delay to Minimize Perfusion in Eyelid Surgery: Measured by Laser-Based Methods and a Novel Form of Extended-Wavelength Diffuse Reflectance Spectroscopy'. Together they form a unique fingerprint.

Cite this