Projects per year
Abstract
The purpose of this study was to compare the non-invasive 3D pseudo-continuous arterial spin labelling (PC ASL) technique with the clinically established dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) for evaluation of brain tumours. A prospective study of 28 patients with contrast-enhancing brain tumours was performed at 3 T using DSC-MRI and PC ASL with whole-brain coverage. The visual qualitative evaluation of signal enhancement in tumour was scored from 0 to 3 (0 = no signal enhancement compared with white matter, 3 = pronounced signal enhancement with equal or higher signal intensity than in grey matter/basal ganglia). The extent of susceptibility artefacts in the tumour was scored from 0 to 2 (0 = no susceptibility artefacts and 2 = extensive susceptibility artefacts (maximum diameter > 2 cm)). A quantitative analysis was performed with normalised tumour blood flow values (ASL nTBF, DSC nTBF): mean value for region of interest (ROI) in an area with maximum signal enhancement/the mean value for ROIs in cerebellum. There was no difference in total visual score for signal enhancement between PC ASL and DSC relative cerebral blood flow (p = 0.12). ASL had a lower susceptibility-artefact score than DSC-MRI (p = 0.03). There was good correlation between DSC nTBF and ASL nTBF values with a correlation coefficient of 0.82. PC ASL is an alternative to DSC-MRI for the evaluation of perfusion in brain tumours. The method has fewer susceptibility artefacts than DSC-MRI and can be used in patients with renal failure because no contrast injection is needed.
Original language | English |
---|---|
Pages (from-to) | 307-317 |
Journal | Neuroradiology |
Volume | 52 |
Issue number | 4 |
DOIs | |
Publication status | Published - 2010 |
Subject classification (UKÄ)
- Radiology, Nuclear Medicine and Medical Imaging
Free keywords
- Brain neoplasms
- DSC-MRI
- ASL
- Magnetic resonance imaging
- Perfusion
Fingerprint
Dive into the research topics of 'Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging'. Together they form a unique fingerprint.-
Optimisation and Validation of Dynamic Susceptibility Contrast MRI
Knutsson, L. (PI) & Wirestam, R. (PI)
1997/01/01 → …
Project: Research
-
MRI brain perfusion quantification at 3 tesla using arterial spin labeling
Knutsson, L. (PI) & Wirestam, R. (PI)
2006/07/02 → 2017/02/17
Project: Research