N2 - One important aspect of antibody separation being studied today is aggregation, as this not only leads to a loss in yield, but aggregates can also be hazardous if injected in to the body. The aim of the study was to determine whether the methodology applied in the previous study could be used to predict the aggregation of a different batch of IgG1, and to model the aggregation occurring in a SEC column. Aggregation was found to be reversible. The equilibrium parameter was found to be 272 M(-1) and the reaction kinetic parameter 1.33·10(-5) s(-1) , both within the 95%percnt; confidence interval of the results obtained in the previous work. The effective diffusivities were estimated to be 1.45·10(-13) and 1.90·10(-14) m(2) /s for the monomers and dimers, respectively. Good agreement was found between the new model and the chromatograms obtained in the SEC experiments. The model was also able to predict the decrease of dimers due to the dilution and separation in the SEC column during long retention times.
AB - One important aspect of antibody separation being studied today is aggregation, as this not only leads to a loss in yield, but aggregates can also be hazardous if injected in to the body. The aim of the study was to determine whether the methodology applied in the previous study could be used to predict the aggregation of a different batch of IgG1, and to model the aggregation occurring in a SEC column. Aggregation was found to be reversible. The equilibrium parameter was found to be 272 M(-1) and the reaction kinetic parameter 1.33·10(-5) s(-1) , both within the 95%percnt; confidence interval of the results obtained in the previous work. The effective diffusivities were estimated to be 1.45·10(-13) and 1.90·10(-14) m(2) /s for the monomers and dimers, respectively. Good agreement was found between the new model and the chromatograms obtained in the SEC experiments. The model was also able to predict the decrease of dimers due to the dilution and separation in the SEC column during long retention times.
UR - https://www.scopus.com/pages/publications/84947025358
U2 - 10.1002/biot.201500160
DO - 10.1002/biot.201500160
M3 - Article
C2 - 26212800
SN - 1860-6768
VL - 10
SP - 1814
EP - 1821
JO - Biotechnology Journal
JF - Biotechnology Journal
IS - 11
ER -