Skip to main navigation Skip to search Skip to main content

Quantitative flow ratio will supplant wire-based physiological indices: pros and cons

  • Aarhus University Hospital
  • Skåne University Hospital

Research output: Contribution to journal › Article › peer-review

Abstract

Quantitative flow ratio (QFR) represents a physiological index derived from angiography through three-dimensional (3D) quantitative coronary analysis. When compared to coronary angiography, QFR showed better performance both for guiding percutaneous coronary intervention (PCI) in case of intermediate coronary lesions and for optimising PCI results. In addition, QFR showed good diagnostic agreement with other established physiological indices, such as fractional flow reserve (FFR), with important practical advantages (e.g., fast and offline analysis). However, data on clinical outcomes in comparisons to wire-based physiological indices as well as validation studies in complex PCI and high-risk scenarios are still lacking. Further research is needed to determine the exact field of application of QFR, and whether it can supplant wire-based physiological indices remains a matter of debate.

Original languageEnglish
Pages (from-to)e1199-e1201
JournalEuroIntervention
Volume20
Issue number19
DOIs
Publication statusPublished - 2024 Oct 7

Subject classification (UKÄ)

  • Cardiology and Cardiovascular Disease

Fingerprint

Dive into the research topics of 'Quantitative flow ratio will supplant wire-based physiological indices: pros and cons'. Together they form a unique fingerprint.