TY - JOUR
T1 - Sentinel Node Procedure in Prostate Cancer
T2 - A Systematic Review to Assess Diagnostic Accuracy
AU - Wit, Esther M K
AU - Acar, Cenk
AU - Grivas, Nikolaos
AU - Yuan, Cathy
AU - Horenblas, Simon
AU - Liedberg, Fredrik
AU - Valdes Olmos, Renato A.
AU - van Leeuwen, Fijs W B
AU - van den Berg, Nynke S.
AU - Winter, Alexander
AU - Wawroschek, Friedhelm
AU - Hruby, Stephan
AU - Janetschek, Günter
AU - Vidal-Sicart, Sergi
AU - MacLennan, Steven
AU - Lam, Thomas B.
AU - van der Poel, Henk G.
PY - 2017
Y1 - 2017
N2 - Context: Extended pelvic lymph node dissection (ePLND) is the gold standard for detecting lymph node (LN) metastases in prostate cancer (PCa). The benefit of sentinel node biopsy (SNB), which is the first draining LN as assessed by imaging of locally injected tracers, remains controversial. Objective: To assess the diagnostic accuracy of SNB in PCa. Evidence acquisition: A systematic literature search of Medline, Embase, and the Cochrane Library (1999-2016) was undertaken using PRISMA guidelines. All studies of SNB in men with PCa using PLND as reference standard were included. The primary outcomes were the nondiagnostic rate (NDR), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and false positive (FP) and false negative (FN) rates. Relevant sensitivity analyses based on SN definitions, ePLND as reference standard, and disease risk were undertaken, including a risk of bias (RoB) assessment. Evidence synthesis: Of 373 articles identified, 21 studies recruiting a total of 2509 patients were eligible for inclusion. Median cumulative percentage (interquartile range) results were 4.1% (1.5-10.7%) for NDR, 95.2% (81.8-100%) for sensitivity, 100% (95.0-100%) for specificity, 100% (87.0-100%) for PPV, 98.0% (94.3-100%) for NPV, 0% (0-5.0%) for the FP rate, and 4.8% (0-18.2%) for the FN rate. The findings did not change significantly on sensitivity analyses. Most studies (17/22) had low RoB for index test and reference standard domains. Conclusions: SNB appears to have diagnostic accuracy comparable to ePLND, with high sensitivity, specificity, PPV and NPV, and a low FN rate. With a low FP rate (rate of detecting positive nodes outside the ePLND template), SNB may not have any additional diagnostic value over and above ePLND, although SNB appears to increase nodal yield by increasing the number of affected nodes when combined with ePLND. Thus, in high-risk disease it may be prudent to combine ePLND with SNB. Patient summary: This literature review showed a high diagnostic accuracy for sentinel node biopsy in detecting positive lymph nodes in prostate cancer, but further studies are needed to explore the effect of sentinel node biopsy on complications and oncologic outcome. The accuracy of sentinel node biopsy (SNB) in detecting positive lymph nodes in prostate cancer appears to have diagnostic accuracy comparable to that of extended pelvic lymph node dissection (ePLND). However, SNB may not have any additional diagnostic value over and above ePLND.
AB - Context: Extended pelvic lymph node dissection (ePLND) is the gold standard for detecting lymph node (LN) metastases in prostate cancer (PCa). The benefit of sentinel node biopsy (SNB), which is the first draining LN as assessed by imaging of locally injected tracers, remains controversial. Objective: To assess the diagnostic accuracy of SNB in PCa. Evidence acquisition: A systematic literature search of Medline, Embase, and the Cochrane Library (1999-2016) was undertaken using PRISMA guidelines. All studies of SNB in men with PCa using PLND as reference standard were included. The primary outcomes were the nondiagnostic rate (NDR), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and false positive (FP) and false negative (FN) rates. Relevant sensitivity analyses based on SN definitions, ePLND as reference standard, and disease risk were undertaken, including a risk of bias (RoB) assessment. Evidence synthesis: Of 373 articles identified, 21 studies recruiting a total of 2509 patients were eligible for inclusion. Median cumulative percentage (interquartile range) results were 4.1% (1.5-10.7%) for NDR, 95.2% (81.8-100%) for sensitivity, 100% (95.0-100%) for specificity, 100% (87.0-100%) for PPV, 98.0% (94.3-100%) for NPV, 0% (0-5.0%) for the FP rate, and 4.8% (0-18.2%) for the FN rate. The findings did not change significantly on sensitivity analyses. Most studies (17/22) had low RoB for index test and reference standard domains. Conclusions: SNB appears to have diagnostic accuracy comparable to ePLND, with high sensitivity, specificity, PPV and NPV, and a low FN rate. With a low FP rate (rate of detecting positive nodes outside the ePLND template), SNB may not have any additional diagnostic value over and above ePLND, although SNB appears to increase nodal yield by increasing the number of affected nodes when combined with ePLND. Thus, in high-risk disease it may be prudent to combine ePLND with SNB. Patient summary: This literature review showed a high diagnostic accuracy for sentinel node biopsy in detecting positive lymph nodes in prostate cancer, but further studies are needed to explore the effect of sentinel node biopsy on complications and oncologic outcome. The accuracy of sentinel node biopsy (SNB) in detecting positive lymph nodes in prostate cancer appears to have diagnostic accuracy comparable to that of extended pelvic lymph node dissection (ePLND). However, SNB may not have any additional diagnostic value over and above ePLND.
KW - Diagnostic accuracy
KW - Pelvic lymph node dissection
KW - Prostate cancer
KW - Sentinel node
KW - Systematic review
KW - Targeted lymph node biopsy
UR - http://www.scopus.com/inward/record.url?scp=84994702072&partnerID=8YFLogxK
U2 - 10.1016/j.eururo.2016.09.007
DO - 10.1016/j.eururo.2016.09.007
M3 - Review article
C2 - 27639533
AN - SCOPUS:84994702072
SN - 0302-2838
VL - 71
SP - 596
EP - 605
JO - European Urology
JF - European Urology
IS - 4
ER -