Spectral intensities as a function of Hg content and measurement position in fluorescent light tubes

Roger Hutton, Sven Huldt, G Zissis, J B Rouffet, S Bhosle

    Research output: Chapter in Book/Report/Conference proceedingPaper in conference proceedingpeer-review

    Abstract

    Summary form only given. Spectra were recorded from a fluorescent light tube under a number of experimental conditions and using different spectroscopic techniques. The motivation of the work was to use spectroscopic techniques for plasma diagnostics purposes. The spectrometers used were a high resolution echelle based instrument and a Fourier transform spectrometer in Lund and a low-resolution instrument in Toulouse. The interest in the low resolution instrument is that it is attached to a temperature controlled bath. The data obtained in Lund was at much higher resolution but not temperature controlled. Spectra were also recorded at a number of positions along the tube. Some of the results can be summarized as follows: (a) spectral lines from ionized Hg decay much faster as a function of temperature than lines from Hg I. This is in some ways unexpected as: (b) the percentage of excited noble gas atoms increases as the lamp temperate, i.e. Hg atom content, goes down, which would appear to indicate that; (c) the electron energy increases as the Hg content (lamp temperature) goes down; (d) From the intensities of noble gas lines as a function of distance from the filament it would appear that the electron temperature is higher close to the filament. One would imagine that the concentration of excited Hg<sup>+</sup> would benefit from a higher electron energy distribution or a higher content of excited noble gas atoms (Penning ionization/excitation). Hence one may expect the Hg<sup>+</sup> excited concentration to follow that of excited Hg, but such is not the case. Some of the above mentioned conclusions, e.g. (c) and (d) are known in the literature from other experimental studies. The other points are the subject of further studies using a combination of high spectral resolution, controlled temperature and time resolved methods
    Original languageEnglish
    Title of host publicationIEEE Conference Record - Abstracts. The 33rd IEEE International Conference on Plasma Science
    PublisherIEEE - Institute of Electrical and Electronics Engineers Inc.
    Pages242-242
    ISBN (Print)1-4244-0124-0
    Publication statusPublished - 2006
    EventThe 33rd IEEE International Conference on Plasma Science - Traverse City, MI, United States
    Duration: 2006 Jun 42006 Jun 8

    Conference

    ConferenceThe 33rd IEEE International Conference on Plasma Science
    Country/TerritoryUnited States
    CityTraverse City, MI
    Period2006/06/042006/06/08

    Subject classification (UKÄ)

    • Astronomy, Astrophysics and Cosmology

    Free keywords

    • Penning excitation
    • time resolved methods
    • Penning ionization
    • electron energy distribution
    • electron temperature
    • excited noble gas atoms
    • temperature controlled bath
    • Fourier transform spectrometer
    • echelle based instrument
    • plasma diagnostics
    • spectral intensities
    • fluorescent light tubes
    • Hg

    Fingerprint

    Dive into the research topics of 'Spectral intensities as a function of Hg content and measurement position in fluorescent light tubes'. Together they form a unique fingerprint.

    Cite this