Abstract
In this study, sample preparation of urinary trans, trans-muconic acid (tt-MA), a minor metabolite and biomarker of benzene, by means of Supported Liquid Membrane (SLM) extraction has been investigated. The sample extract was automatically transferred on-line to an ion exchange chromatographic column and the analytes were detected using a photodiode array detector. Automation of the system was accomplished using a robotic sample preparation processor integrated into the chromatographic system. Detection limits calculated from the baseline noise was in the sub-ppb range, and quantification of tt-MA is safe down to 10 ppb.
Original language | English |
---|---|
Pages (from-to) | 351-355 |
Journal | Journal of Separation Science |
Volume | 25 |
Issue number | 5-6 |
DOIs | |
Publication status | Published - 2002 |
Bibliographical note
The information about affiliations in this record was updated in December 2015.The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
Subject classification (UKÄ)
- Analytical Chemistry
Free keywords
- extraction
- supported liquid membrane
- benzene exposure
- biomarker
- muconic acid