The comparative relationships between locations of the papillary muscles and electrophysiologic QRS axis in patients with atrioventricular septal defect and common as opposed to separate orifices in the valve guarding the common atrioventricular junction

Liying Low, Salim F. Idriss, Robert H. Anderson, Charles Maynard, Galen Wagner, Nina Hakacova

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Knowledge regarding factors that influence deviation of the QRS axis is important when seeking to differentiate between physiological and pathological changes. We hypothesised that, in contrast to those patients with an atrioventricular septal defect and common atrioventricular junction permitting only atrial shunting, those associated with ventricular shunting would show no relationship between the positions of the papillary muscles and the degree of the leftward deviation of the QRS axis. Methods: We compared the positions of endocardial origin of the papillary muscles, and the frontal plane QRS axis, in patients with atrioventricular septal defects and common atrioventricular junction permitting exclusively atrial as opposed to atrial and ventricular shunting. Results: We analysed 18 patients with atrial and ventricular shunting and 23 patients with exclusively atrial shunting. The correlation coefficient between the ratio of distances of the papillary muscles from the mid-septum and the amount of leftward deviation in the frontal plane QRS axis was 0.1 (p=0.4) in those with ventricular shunting and 0.26 (p=0.01) in those with exclusively atrial shunting. Conclusions: In contrast to patients with the so-called primum form of atrioventricular septal defect, in whom the locations of the papillary muscles correlate with the degree of QRS axis, such relationships are lacking in patients with defects permitting both atrial and ventricular shunting. It may be, therefore, that the presence of ventricular shunting and/or their younger age causes pressure overload, which negates the leftward QRS forces caused by the abnormally positioned papillary muscles.

Original languageEnglish
Pages (from-to)261-266
JournalCardiology in the Young
Volume27
Issue number2
DOIs
Publication statusPublished - 2017

Subject classification (UKÄ)

  • Cardiac and Cardiovascular Systems

Free keywords

  • atrioventricular septal defect
  • papillary muscles
  • QRS axis

Fingerprint

Dive into the research topics of 'The comparative relationships between locations of the papillary muscles and electrophysiologic QRS axis in patients with atrioventricular septal defect and common as opposed to separate orifices in the valve guarding the common atrioventricular junction'. Together they form a unique fingerprint.

Cite this