T1 - The role of breast tomosynthesis in a predominantly dense breast population at a tertiary breast centre
T2 - breast density assessment and diagnostic performance in comparison with MRI
AU - Förnvik, Daniel
AU - Kataoka, Masako
AU - Iima, Mami
AU - Ohashi, Akane
AU - Kanao, Shotaro
AU - Toi, Masakazu
AU - Togashi, Kaori
PY - 2018/8
Y1 - 2018/8
N2 - Objectives: To compare breast density measured on digital breast tomosynthesis (DBT) (BI-RADS-based breast composition and fully-automatic estimation) and magnetic resonance imaging (MRI) (BI-RADS amount of fibroglandular tissue), and to evaluate the diagnostic performance in terms of sensitivity and specificity of DBT and MRI in a predominantly dense breast population. Methods: Between 2015 and 2016, 152 women with 103 breast malignancies, who underwent 3-T breast MRI and DBT within 2 months’ time, were enrolled in this study. Breast composition/fibroglandular tissue and findings on DBT (two readers) and MRI were reported using BI-RADS 5th edition. Digital mammography images were analysed for breast percent density (PD) using the Libra software tool. Results: A majority of women had dense breasts as categorised by breast composition c (heterogeneously dense) (68%) and d (extremely dense) (15%). The mean PD was 44% (range, 18-89%) and the correlation between breast composition and PD was r = 0.6. The diagnostic performance of MRI was significantly higher compared to DBT for one reader as described by the area under the receiver operating characteristic (ROC) curve (p = 0.004) and of borderline significance for the other reader (p = 0.052). Conclusions: MRI had higher diagnostic performance than DBT in a dense breast population in the tertiary setting. Key Points: • MRI had higher diagnostic performance than DBT in a dense breast population• Diagnostic performance of DBT was comparable to MRI in women with fatty breasts• MRI was superior to DBT in preoperative breast cancer size assessment
AB - Objectives: To compare breast density measured on digital breast tomosynthesis (DBT) (BI-RADS-based breast composition and fully-automatic estimation) and magnetic resonance imaging (MRI) (BI-RADS amount of fibroglandular tissue), and to evaluate the diagnostic performance in terms of sensitivity and specificity of DBT and MRI in a predominantly dense breast population. Methods: Between 2015 and 2016, 152 women with 103 breast malignancies, who underwent 3-T breast MRI and DBT within 2 months’ time, were enrolled in this study. Breast composition/fibroglandular tissue and findings on DBT (two readers) and MRI were reported using BI-RADS 5th edition. Digital mammography images were analysed for breast percent density (PD) using the Libra software tool. Results: A majority of women had dense breasts as categorised by breast composition c (heterogeneously dense) (68%) and d (extremely dense) (15%). The mean PD was 44% (range, 18-89%) and the correlation between breast composition and PD was r = 0.6. The diagnostic performance of MRI was significantly higher compared to DBT for one reader as described by the area under the receiver operating characteristic (ROC) curve (p = 0.004) and of borderline significance for the other reader (p = 0.052). Conclusions: MRI had higher diagnostic performance than DBT in a dense breast population in the tertiary setting. Key Points: • MRI had higher diagnostic performance than DBT in a dense breast population• Diagnostic performance of DBT was comparable to MRI in women with fatty breasts• MRI was superior to DBT in preoperative breast cancer size assessment
KW - Breast cancer
KW - Breast density
KW - Diagnostic techniques and procedures
KW - Digital breast tomosynthesis
KW - Magnetic resonance imaging
UR - http://www.scopus.com/inward/record.url?scp=85042173743&partnerID=8YFLogxK
U2 - 10.1007/s00330-017-5297-7
DO - 10.1007/s00330-017-5297-7
M3 - Article
C2 - 29460074
AN - SCOPUS:85042173743
SN - 0938-7994
VL - 28
SP - 3194
EP - 3203
JO - European Radiology
JF - European Radiology
IS - 8
ER -