N2 - Introduction The spatial peaks QRS-T angle has been shown to differentiate adult patients with hypertrophic cardiomyopathy (HCM) from controls. We hypothesized that the spatial peaks QRS-T angle would, in isolation, be more accurate than the Italian 12-lead ECG Pre-participation Screening criteria or the Seattle criteria for detecting hypertrophic cardiomyopathy (HCM) in pediatric patients. Methods A retrospective study of pediatric patients with HCM compared to age and gender-matched control patients was undertaken. Significance, odds ratios, sensitivity and specificity of HCM detection of the visually derived spatial peaks QRS-T angle were compared to those of traditional 12-lead ECG criteria using: 1) Italy's National Pre-participation Screening Programme criteria; and 2) described criteria from Seattle. Results ECG results from 130 pediatric HCM patients (14.2 ± 4.4 years) were compared to 470 control patients (normal echocardiograms, mean age 13.4 ± 4.6 years). Mean ± standard deviation (SD) values for spatial peaks QRS-T angles were 120.4 ± 40.7 and 21.3 ± 13.7 degrees for HCM and controls, respectively (P < 0.001). A spatial peaks QRS-T angle cutoff value of > 54.9 degrees yielded greater sensitivity and specificity (93.1% and 98.7%, respectively) for detecting HCM over ECG criteria from Italy (68.5% and 48.1%, respectively) or Seattle (64.6% and 78.9%, respectively) with odds ratios at 1039.70 (95% CI 363.03 to 2977.67), 2.01 (95% CI 1.33 to 3.04) and 6.84 (4.49-10.44), respectively. Conclusion In our cohort, a visually derived spatial peaks QRS-T angle has increased sensitivity and specificity for detection of HCM in pediatric patients compared to currently utilized Italian or Seattle ECG criteria.
AB - Introduction The spatial peaks QRS-T angle has been shown to differentiate adult patients with hypertrophic cardiomyopathy (HCM) from controls. We hypothesized that the spatial peaks QRS-T angle would, in isolation, be more accurate than the Italian 12-lead ECG Pre-participation Screening criteria or the Seattle criteria for detecting hypertrophic cardiomyopathy (HCM) in pediatric patients. Methods A retrospective study of pediatric patients with HCM compared to age and gender-matched control patients was undertaken. Significance, odds ratios, sensitivity and specificity of HCM detection of the visually derived spatial peaks QRS-T angle were compared to those of traditional 12-lead ECG criteria using: 1) Italy's National Pre-participation Screening Programme criteria; and 2) described criteria from Seattle. Results ECG results from 130 pediatric HCM patients (14.2 ± 4.4 years) were compared to 470 control patients (normal echocardiograms, mean age 13.4 ± 4.6 years). Mean ± standard deviation (SD) values for spatial peaks QRS-T angles were 120.4 ± 40.7 and 21.3 ± 13.7 degrees for HCM and controls, respectively (P < 0.001). A spatial peaks QRS-T angle cutoff value of > 54.9 degrees yielded greater sensitivity and specificity (93.1% and 98.7%, respectively) for detecting HCM over ECG criteria from Italy (68.5% and 48.1%, respectively) or Seattle (64.6% and 78.9%, respectively) with odds ratios at 1039.70 (95% CI 363.03 to 2977.67), 2.01 (95% CI 1.33 to 3.04) and 6.84 (4.49-10.44), respectively. Conclusion In our cohort, a visually derived spatial peaks QRS-T angle has increased sensitivity and specificity for detection of HCM in pediatric patients compared to currently utilized Italian or Seattle ECG criteria.
KW - Italian criteria
KW - Screening
KW - Seattle criteria
KW - Vectorcardiography
UR - http://www.scopus.com/inward/record.url?scp=84941314078&partnerID=8YFLogxK
U2 - 10.1016/j.jelectrocard.2015.07.016
DO - 10.1016/j.jelectrocard.2015.07.016
M3 - Article
AN - SCOPUS:84941314078
SN - 0022-0736
VL - 48
SP - 826
EP - 833
JO - Journal of Electrocardiology
JF - Journal of Electrocardiology
IS - 5
ER -