Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.

Jonathan Sobocinski, Joseph V Lombardi, Nuno Dias, Ludovic Berger, Qing Zhou, Feiyi Jia, Tim Resch, Stéphan Haulon

Research output: Contribution to journalArticlepeer-review

Abstract

This study compared the 12-month evolution of the aortic volume in patients who underwent thoracic endovascular aortic repair (TEVAR) with stent grafts alone or a composite device (Zenith TX2 stent graft and Zenith Dissection stent; Cook Medical, Bloomington, Ind) for acute (≤2 weeks from onset) complicated type B aortic dissection.
Original languageEnglish
Pages (from-to)1216-1224
JournalJournal of Vascular Surgery
Volume63
Issue number5
Early online date2016 Jan 21
DOIs
Publication statusPublished - 2016

Subject classification (UKÄ)

  • Surgery

Fingerprint

Dive into the research topics of 'Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.'. Together they form a unique fingerprint.