TY - JOUR
T1 - Why is it so difficult to study magnetic compass orientation in murine rodents?
AU - Phillips, John
AU - Muheim, Rachel
AU - Painter, Michael
AU - Raines, Jenny
AU - Anderson, Chris
AU - Landler, Lukas
AU - Dommer, Dave
AU - Raines, Adam
AU - Deutschlander, Mark
AU - Whitehead, John
AU - Fitzpatrick, Nicole Edgar
AU - Youmans, Paul
AU - Borland, Chris
AU - Sloan, Kelly
AU - McKenna, Kaitlyn
N1 - Publisher Copyright:
© 2021, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2022
Y1 - 2022
N2 - A magnetic compass sense has been demonstrated in all major classes of vertebrates, as well as in many invertebrates. In mammals, controlled laboratory studies of mice have provided evidence for a robust magnetic compass that is comparable to, or exceeds, the performance of that in other animals. Nevertheless, the vast majority of laboratory studies of spatial behavior and cognition in murine rodents have failed to produce evidence of sensitivity to magnetic cues. Given the central role that a magnetic compass sense plays in the spatial ecology and cognition of non-mammalian vertebrates, and the potential utility that a global/universal reference frame derived from the magnetic field would have in mammals, the question of why responses to magnetic cues have been so difficult to demonstrate reliably is of considerable importance. In this paper, we review evidence that the magnetic compass of murine rodents shares a number of properties with light-dependent compasses in a wide variety of other animals generally believed to be mediated by a radical pair mechanism (RPM) or related quantum process. Consistent with the RPM, we summarize both published and previously unpublished findings suggesting that the murine rodent compass is sensitive to low-level radio frequency (RF) fields. Finally, we argue that the presence of anthropogenic RF fields in laboratory settings, may be an important source of variability in responses of murine rodents to magnetic cues.
AB - A magnetic compass sense has been demonstrated in all major classes of vertebrates, as well as in many invertebrates. In mammals, controlled laboratory studies of mice have provided evidence for a robust magnetic compass that is comparable to, or exceeds, the performance of that in other animals. Nevertheless, the vast majority of laboratory studies of spatial behavior and cognition in murine rodents have failed to produce evidence of sensitivity to magnetic cues. Given the central role that a magnetic compass sense plays in the spatial ecology and cognition of non-mammalian vertebrates, and the potential utility that a global/universal reference frame derived from the magnetic field would have in mammals, the question of why responses to magnetic cues have been so difficult to demonstrate reliably is of considerable importance. In this paper, we review evidence that the magnetic compass of murine rodents shares a number of properties with light-dependent compasses in a wide variety of other animals generally believed to be mediated by a radical pair mechanism (RPM) or related quantum process. Consistent with the RPM, we summarize both published and previously unpublished findings suggesting that the murine rodent compass is sensitive to low-level radio frequency (RF) fields. Finally, we argue that the presence of anthropogenic RF fields in laboratory settings, may be an important source of variability in responses of murine rodents to magnetic cues.
KW - Low-level RF fields
KW - Magnetic compass
KW - Murine rodents
KW - Radical pair mechanism
U2 - 10.1007/s00359-021-01532-z
DO - 10.1007/s00359-021-01532-z
M3 - Review article
C2 - 35094127
AN - SCOPUS:85123838326
SN - 0340-7594
VL - 208
SP - 197
EP - 212
JO - Journal of Comparative Physiology A: Neuroethology, Sensory, Neural, and Behavioral Physiology
JF - Journal of Comparative Physiology A: Neuroethology, Sensory, Neural, and Behavioral Physiology
IS - 1
ER -