Dystrophia Helsinglandica - corneal morphology, topography and sensitivity in a hereditary corneal disease with recurrent erosive episodes

Research output: Contribution to journalArticle

Standard

Dystrophia Helsinglandica - corneal morphology, topography and sensitivity in a hereditary corneal disease with recurrent erosive episodes. / Neira, Waldir; Hammar, Björn; Holopainen, Juha M.; Tuisku, Ilpo; Dellby, Anette; Tervo, Timo; Fagerholm, Per.

In: Acta Ophthalmologica, Vol. 88, No. 4, 2010, p. 401-406.

Research output: Contribution to journalArticle

Harvard

APA

CBE

MLA

Vancouver

Author

Neira, Waldir ; Hammar, Björn ; Holopainen, Juha M. ; Tuisku, Ilpo ; Dellby, Anette ; Tervo, Timo ; Fagerholm, Per. / Dystrophia Helsinglandica - corneal morphology, topography and sensitivity in a hereditary corneal disease with recurrent erosive episodes. In: Acta Ophthalmologica. 2010 ; Vol. 88, No. 4. pp. 401-406.

RIS

TY - JOUR

T1 - Dystrophia Helsinglandica - corneal morphology, topography and sensitivity in a hereditary corneal disease with recurrent erosive episodes

AU - Neira, Waldir

AU - Hammar, Björn

AU - Holopainen, Juha M.

AU - Tuisku, Ilpo

AU - Dellby, Anette

AU - Tervo, Timo

AU - Fagerholm, Per

PY - 2010

Y1 - 2010

N2 - Purpose: The aim of this study was to describe the morphology, corneal topography and sensitivity in individuals with Dystrophia Helsinglandica. This autosomal dominant corneal disease is characterized by recurrent corneal erosive episodes and progressive subepithelial fibrosis not significantly affecting visual acuity. Methods: The corneas of nine affected and nine unaffected individuals were examined using slit-lamp biomicroscopy, in vivo confocal microscopy (IVCM) and videokeratography. Corneal mechanical sensitivity was also measured using a non-contact esthesiometer. Results: Slit-lamp biomicroscopy revealed that the affected individuals represented different stages of corneal changes, from a nearly normal cornea to subepithelial fibrosis of the central cornea. Corneal changes in affected individuals did not significantly decrease the best spectacle-corrected visual acuity. In vivo confocal microscopy detected morphological changes in the epithelium and stroma. Subepithelial opacity formation including altered keratocytes could be found in the anterior stroma in all affected eyes. With the exception of two eyes (one affected and one unaffected), all videokeratographies showed irregular astigmatism. Corneal sensitivity was significantly lower in affected individuals (p = 0.01). Age and corneal sensitivity showed no correlation. Conclusion: The main morphological findings in affected individuals were discrete and progressive subepithelial fibrosis, in the in vivo confocal microscope corresponding to optically dense extracellular matrix and activated keratocytes. Subbasal nerve morphology was changed in the affected family members who also showed a decreased corneal sensitivity. The findings are per se not specific to the disease. The changes probably reflect a healing response to erosive events on the corneal surface influenced by the genotype.

AB - Purpose: The aim of this study was to describe the morphology, corneal topography and sensitivity in individuals with Dystrophia Helsinglandica. This autosomal dominant corneal disease is characterized by recurrent corneal erosive episodes and progressive subepithelial fibrosis not significantly affecting visual acuity. Methods: The corneas of nine affected and nine unaffected individuals were examined using slit-lamp biomicroscopy, in vivo confocal microscopy (IVCM) and videokeratography. Corneal mechanical sensitivity was also measured using a non-contact esthesiometer. Results: Slit-lamp biomicroscopy revealed that the affected individuals represented different stages of corneal changes, from a nearly normal cornea to subepithelial fibrosis of the central cornea. Corneal changes in affected individuals did not significantly decrease the best spectacle-corrected visual acuity. In vivo confocal microscopy detected morphological changes in the epithelium and stroma. Subepithelial opacity formation including altered keratocytes could be found in the anterior stroma in all affected eyes. With the exception of two eyes (one affected and one unaffected), all videokeratographies showed irregular astigmatism. Corneal sensitivity was significantly lower in affected individuals (p = 0.01). Age and corneal sensitivity showed no correlation. Conclusion: The main morphological findings in affected individuals were discrete and progressive subepithelial fibrosis, in the in vivo confocal microscope corresponding to optically dense extracellular matrix and activated keratocytes. Subbasal nerve morphology was changed in the affected family members who also showed a decreased corneal sensitivity. The findings are per se not specific to the disease. The changes probably reflect a healing response to erosive events on the corneal surface influenced by the genotype.

KW - corneal sensitivity

KW - corneal dystrophies

KW - confocal microscopy

KW - cornea

KW - videokeratography

KW - morphology

U2 - 10.1111/j.1755-3768.2009.01844.x

DO - 10.1111/j.1755-3768.2009.01844.x

M3 - Article

C2 - 20597871

VL - 88

SP - 401

EP - 406

JO - Acta Ophthalmologica

JF - Acta Ophthalmologica

SN - 1755-3768

IS - 4

ER -