Increased apparatus dead space and tidal volume increase blood concentrations of oxygen and sevoflurane in overweight patients: a randomised controlled clinical study.

Research output: Contribution to journalArticle

Abstract

General anaesthesia impairs respiratory function in overweight patients. We wanted to determine whether increased tidal volume (VT), with unchanged end-tidal carbon dioxide partial pressure (PETCO2), affects blood concentrations of oxygen and sevoflurane in overweight patients.

Details

Authors
Organisations
Research areas and keywords

Subject classification (UKÄ) – MANDATORY

  • Anesthesiology and Intensive Care
Original languageEnglish
Pages (from-to)382-386
JournalEuropean Journal of Anaesthesiology
Volume28
Issue number5
Publication statusPublished - 2011
Publication categoryResearch
Peer-reviewedYes

Bibliographic note

The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Anaesthesiology and Intensive Care (013230022), Division of Nursing (Closed 2012) (013065000)

Total downloads