In-plane artifacts in breast tomosynthesis quantified with a novel contrast-detail phantom

Research output: Chapter in Book/Report/Conference proceedingPaper in conference proceeding

Abstract

The purpose of this work was to develop a contrast-detail phantom that can be used to evaluate image quality in breast tomosynthesis (BT) and as a first step use it to evaluate in-plane artifacts with respect to object size and contrast. The phantom was constructed using a Polylite [registered trademark] resin as bulk material, as it has x-ray mass attenuation properties similar to polymethyl methacrylate (PMMA), a common phantom material in mammography. Six different materials polyoxymethylene (POM), bakelite [registered trademark] , nylon, polycarbonate (PC), acrylonitrilebutadienestyrene (ABS) and polyethene (PE) - were selected to form the phantom details. For each of the six materials, five spherical objects were manufactured (diameters of 4, 8, 12, 16, and 20 mm) resulting in 30 objects that were embedded with their centres approximately aligned at the central plane of a 26 mm thick Polylite [registered trademark] block (210 mm × 300 mm). A 20 mm thick PMMA block was added to yield a phantom with attenuation properties similar to 45 mm PMMA that could simulate a so-called standard breast (50 mm thick, 50% glandular tissue). Images of the phantom were acquired using a BT prototype system that employs filtered backprojection for image reconstruction. The magnitude of the in-plane artifacts was evaluated and was found to increase linearly with increasing contrast (signal) level and size of the embedded objects. The contrast-detail phantom was found to be a useful tool for evaluating BT in-plane artifacts and might also be used to study out-of-plane artifacts and the effect of different acquisition and reconstruction parameters on image quality in BT.

Details

Authors
Organisations
Research areas and keywords

Subject classification (UKÄ) – MANDATORY

  • Radiology, Nuclear Medicine and Medical Imaging

Keywords

  • Digital mammography, Breast tomosynthesis, 3D phantom
Original languageEnglish
Title of host publicationProgress in Biomedical Optics and Imaging - Proceedings of SPIE
PublisherSPIE
PagesU1853-U1864
Volume6510
Publication statusPublished - 2007
Publication categoryResearch
Peer-reviewedYes
EventMedical Imaging 2007: Physics of Medical Imaging - San Diego, CA, United States
Duration: 2007 Feb 182007 Feb 22

Publication series

Name
NumberPART 3
Volume6510
ISSN (Print)1042-4687
ISSN (Electronic)1605-7422

Conference

ConferenceMedical Imaging 2007: Physics of Medical Imaging
CountryUnited States
CitySan Diego, CA
Period2007/02/182007/02/22