Spot immunoprecipitate assay in gel compared with immune reactions in solution and applied to antibody titration

Research output: Contribution to journalArticle

Abstract

Precipitation profiles of spot immunoprecipitate assay (SIA) reactions in gel are shown to have characteristics analogous to classic precipitin curves representing such immune reactions in solution. Thus SIA profiles of precipitated human albumin (HSA) and anti-HSA as checkerboard analysis permit: (1) determination of optimal proportions of antibody and antigen, (2) titration of antiserum as to antigen-binding capacity and (3) estimation of the concentration of specific antibody in an antiserum. The validity of the method was confirmed by similar results already reported for precipitin analysis of anti-HSA in solution. The stained protein assay method for determination of total protein used for the calculations had a reliable (r = 0.9979) working range for quantification between 0.1 and 0.83 microgram protein in 3 microliters samples (greater than or equal to 0.03 g/l). Study of SIA profiles in the extreme antibody excess region confirmed the validity of SIA quantification. The high sensitivity of SIA as compared with radial immunodiffusion is related to high ratios (8-9) of antibody to antigen; the reliable detection limit for SIA is 10 mg/l in a 3 microliters sample. SIA is easy to perform with simple laboratory equipment, allows measurement of any precipitable antigen with very small amounts of reactants, and gives results within an hour.

Details

Authors
Organisations
Research areas and keywords

Subject classification (UKÄ) – MANDATORY

  • Immunology in the medical area

Keywords

  • antibody titration, precipitation in gel, optimal proportion of antigen and antibody, antigen-antibody reaction
Original languageEnglish
Pages (from-to)217-229
JournalJournal of Immunological Methods
Volume62
Issue number2
Publication statusPublished - 1983
Publication categoryResearch
Peer-reviewedYes

Bibliographic note

The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Bioimplant Research (013242910)