The new septum magnets

Research output: Contribution to journalArticle

Abstract

In an earlier paper we reported on a new septum magnet design with a magnetic flux filter [1]. Now the first septum magnet is in operation as in injection septum magnet for the MAX I storage ring. We dcscribe the actual mechanical construction and the field measurements of the new magnets. The fine Structure of the septum nose needed several trials in the construction until we found the final solution. The measured residual stray fields in the ring tube are even smaller than was expected from the model calculations.

Details

Authors
  • Lars-Johan Lindgren
  • B Anderberg
Organisations
Research areas and keywords

Subject classification (UKÄ) – MANDATORY

  • Accelerator Physics and Instrumentation

Keywords

  • storage ring, septum, accelerator, magnet, injection
Original languageEnglish
Pages (from-to)686-689
JournalNuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
Volume547
Issue number2-3
Publication statusPublished - 2005
Publication categoryResearch
Peer-reviewedYes