A simplified non-linear model of a drum boiler - turbine unit

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskrift

Abstract

In the analysis of power systems it is highly desirable to have models of the different power generators. In this paper we present, a model for a drum boiler whose purpose is to describe the gross behaviour of the boiler. The major control variables are fuel flow and control valve setting. The output variables are drum pressure and active output power. The model is verified by experiments on a 160 Mw boiler.

Detaljer

Författare
Enheter & grupper
Forskningsområden

Ämnesklassifikation (UKÄ) – OBLIGATORISK

  • Reglerteknik
Originalspråkengelska
Sidor (från-till)145-169
TidskriftInternational Journal of Control
Volym16
Utgåva nummer1
StatusPublished - 1972
PublikationskategoriForskning
Peer review utfördJa

Nedladdningar

Ingen tillgänglig data