Can we reduce the workload of mammographic screening by automatic identification of normal exams with artificial intelligence? A feasibility study

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskrift

Bibtex

@article{6bb8282712ed4749bf5da07aa4e52bec,
title = "Can we reduce the workload of mammographic screening by automatic identification of normal exams with artificial intelligence? A feasibility study",
abstract = "Purpose: To study the feasibility of automatically identifying normal digital mammography (DM) exams with artificial intelligence (AI) to reduce the breast cancer screening reading workload. Methods and materials: A total of 2652 DM exams (653 cancer) and interpretations by 101 radiologists were gathered from nine previously performed multi-reader multi-case receiver operating characteristic (MRMC ROC) studies. An AI system was used to obtain a score between 1 and 10 for each exam, representing the likelihood of cancer present. Using all AI scores between 1 and 9 as possible thresholds, the exams were divided into groups of low- and high likelihood of cancer present. It was assumed that, under the pre-selection scenario, only the high-likelihood group would be read by radiologists, while all low-likelihood exams would be reported as normal. The area under the reader-averaged ROC curve (AUC) was calculated for the original evaluations and for the pre-selection scenarios and compared using a non-inferiority hypothesis. Results: Setting the low/high-likelihood threshold at an AI score of 5 (high likelihood > 5) results in a trade-off of approximately halving (− 47%) the workload to be read by radiologists while excluding 7% of true-positive exams. Using an AI score of 2 as threshold yields a workload reduction of 17% while only excluding 1% of true-positive exams. Pre-selection did not change the average AUC of radiologists (inferior 95% CI > − 0.05) for any threshold except at the extreme AI score of 9. Conclusion: It is possible to automatically pre-select exams using AI to significantly reduce the breast cancer screening reading workload. Key Points: • There is potential to use artificial intelligence to automatically reduce the breast cancer screening reading workload by excluding exams with a low likelihood of cancer. • The exclusion of exams with the lowest likelihood of cancer in screening might not change radiologists{\textquoteright} breast cancer detection performance. • When excluding exams with the lowest likelihood of cancer, the decrease in true-positive recalls would be balanced by a simultaneous reduction in false-positive recalls.",
keywords = "Artificial intelligence, Breast cancer, Deep learning, Mammography, Screening",
author = "Alejandro Rodriguez-Ruiz and Kristina L{\aa}ng and Albert Gubern-Merida and Jonas Teuwen and Mireille Broeders and Gisella Gennaro and Paola Clauser and Helbich, {Thomas H.} and Margarita Chevalier and Thomas Mertelmeier and Wallis, {Matthew G.} and Ingvar Andersson and Sophia Zackrisson and Ioannis Sechopoulos and Mann, {Ritse M.}",
year = "2019",
doi = "10.1007/s00330-019-06186-9",
language = "English",
volume = "29",
pages = "4825--4832",
journal = "European Radiology",
issn = "0938-7994",
publisher = "Springer",
number = "9",

}