Lack of diffuse loss of differential light sensitivity in early glaucoma

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskrift

Abstract

We studied the differential light sensitivity in 83 patients who were prospectively followed with computerized threshold preimetry and optic disc pathography because of suspect glaucoma. Eyes with media opacities were excluded from the analysis. Fourteen eyes developed progressive optic disc cupping and/or localized visual field loss. In this glaucoma group light sensitivity in the 10 best points in the visual field did not deviate more from estimated age-corrected standard values than in the remaining groups of 115 eyes with increased intraocular pressure and 18 normotensive eyes. The results do not support the concept that diffuse loss of differential light sensitivity should be common in early glaucoma.

Detaljer

Författare
Enheter & grupper
Externa organisationer
  • Skåne University Hospital
Forskningsområden

Ämnesklassifikation (UKÄ) – OBLIGATORISK

  • Oftalmologi

Nyckelord

Originalspråkengelska
Sidor (från-till)353-60
Antal sidor8
TidskriftActa Ophthalmologica
Volym67
Utgåva nummer4
StatusPublished - 1989 aug
PublikationskategoriForskning
Peer review utfördJa