Neck-bridge device for combined endovascular and surgical treatment of a giant anterior communicating artery aneurysm

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskrift

Abstract

We report the case of a 58-year-old man with a giant partially thrombosed anterior communicating artery aneurysm, which presented with mass effect. Our treatment strategy consisted of endovascular aneurysm circulatory exclusion prior to surgical resection. To do so, we first occluded both the two A1 segments and the aneurysm neck with a neck-bridge device to prevent further coil migration within the aneurysm sac. Five days later, the aneurysm was surgically removed.

Detaljer

Författare
  • C Mounayer
  • Per Undrén
  • M Piotin
  • H Boissonnet
  • J Moret
Enheter & grupper
Forskningsområden

Ämnesklassifikation (UKÄ) – OBLIGATORISK

  • Klinisk medicin

Nyckelord

Originalspråkengelska
Sidor (från-till)295-299
TidskriftNeuroradiology
Volym47
Utgåva nummer4
StatusPublished - 2005
PublikationskategoriForskning
Peer review utfördJa