Oxygen supply to immobilized cells - 3. Oxygen supply by hemoglobin or emulsions of perfluorochemicals

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskrift

Abstract

Oxygen supply is a critical point in technical processes when aerobic cells are used in immobilized preparations. This report concerns the use of hemoglobin or emulsions of perfluorochemicals (completely fluorinated organic compounds) to carry oxygen to immobilized cells. Both methods work well and do not seem to harm the cells. The perfluorochemical method of improving oxygen supply showed a higher operational stability than the hemoglobin method.

Detaljer

Författare
Enheter & grupper
Forskningsområden

Ämnesklassifikation (UKÄ) – OBLIGATORISK

  • Annan industriell bioteknik
Originalspråkengelska
Sidor (från-till)165-170
Antal sidor6
TidskriftEuropean Journal of Applied Microbiology and Biotechnology
Volym16
Utgåva nummer4
StatusPublished - 1982 dec 1
PublikationskategoriForskning
Peer review utfördJa