Time-gated x-ray tomography

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskrift

Abstract

Time-gated x-ray tomography with scatter reduction is demonstrated using a laser-produced plasma as an ultrashort-pulse x-ray source in combination with a time-resolving streak-camera detector. Backprojections of a phantom imbedded in 9 cm of water show an effective 50% increase in contrast when scattered x-ray quanta (being delayed in time) are suppressed by gating on the prompt, nonscattered photons. Implications for future volumetric tomography, in particular concerning possible dose reductions, are discussed. (C) 1998 American Institute of Physics. [S0003-6951(98)02846-0].