Sammanfattning
BACKGROUND: The primary objective was to investigate the clinical and radiological outcome in patients undergoing major hip surgery using a novel antibiotic containing bone substitute for local augmentation in trochanteric fracture fixation or revision of total hip arthroplasty (THA).
METHODS: We implanted a novel biphasic bone substitute CERAMENT™|G consisting of hydroxyapatite, calcium sulphate and gentamicin for bone regeneration and local antibiotic delivery in 20 patients treated surgically for trochanteric femoral fracture or uncemented hip revision. Preoperative, postoperative, 3 months and 1 year clinical and radiological assessment were performed including registration of any complications. In one trochanteric fracture patient, histological analyses were performed of bone biopsies taken at removal of hardware.
RESULTS: None of the trochanteric fractures or revision of THA showed any large migration. No local wound disturbances were seen and no infection was observed at one year follow-up. All trochanteric fractures healed at 3 months with a minimal sliding screw displacement on average 3 mm. Radiological analysis showed signs of bone remodeling and new bone formation in the substitute, illustrated also by histology in the biopsies taken from one trochanteric fracture at one year post-op.
CONCLUSIONS: Local CERAMENT™|G was shown to be safe in a limited prospective major hip surgery study. Remodeling of the bone graft substitute was observed in all patients.
TRIAL REGISTRATION: EU-CTR2018-004414-18 Retrospectively registered on November 20, 2018.
Originalspråk | engelska |
---|---|
Artikelnummer | 438 |
Sidor (från-till) | 438 |
Tidskrift | BMC Musculoskeletal Disorders |
Volym | 19 |
Nummer | 1 |
DOI | |
Status | Published - 2018 dec. 6 |
Ämnesklassifikation (UKÄ)
- Ortopedi