Sammanfattning
The O-arm system is a mobile intraoperative imaging system that is comprised of fluoroscopy and cone beam CT. The configuration of the O-arm system with absence of patient table and a broad beam width (165 mm in isocenter) brings new practical and physical requirements on how to perform dose measurements. The purpose of this study was to describe a method that overcomes this and makes it possible to characterize the radiation output from the O-arm system. A holder with a clamp and a flexible ball joint that can orientate the radiation detector support and the Mover that can be adjusted to hold the dose detector in a horizontal position was used. Evaluation of the dose response for three different dose detectors of different active length (0.3, 23.1 and 100 mm) was made for three different beam qualities. Furthermore the dose profile free in air to control the possible heel effect and width of the x-ray field during rotation was measured and the dose rate waveform was analyzed. The FWHM of the dose profile was 162 mm The dose response of the three detectors is reported. The average dose response was lower for the detector with longer active length due to the influence of the dose profile shape. From dynamic measurement total exposure time, pulse width, and the number of pulses were verified. In conclusion, an external horizontal hanging holder with mover option helps to assist to make dose measurement easier and enables characterize the radiation output from the O-arm system.
| Originalspråk | engelska |
|---|---|
| Titel på värdpublikation | Medical Imaging 2013: Physics of Medical Imaging |
| Förlag | SPIE |
| Sidor | 86682Q |
| Antal sidor | 6 |
| Volym | 8668 |
| ISBN (tryckt) | 9780819494429 |
| DOI | |
| Status | Published - 2013 |
| Evenemang | SPIE Medical Imaging, 2013 - Lake Buena Vista, FL, Lake Buena Vista (Orlando area), Florida, USA Varaktighet: 2013 feb. 9 → 2013 feb. 14 |
Publikationsserier
| Namn | |
|---|---|
| Volym | 8668 |
| ISSN (tryckt) | 1996-756X |
| ISSN (elektroniskt) | 0277-786X |
Konferens
| Konferens | SPIE Medical Imaging, 2013 |
|---|---|
| Land/Territorium | USA |
| Ort | Lake Buena Vista (Orlando area), Florida |
| Period | 2013/02/09 → 2013/02/14 |
Ämnesklassifikation (UKÄ)
- Radiologi och bildbehandling
Fingeravtryck
Utforska forskningsämnen för ”A method to characterize the radiation output from a cone beam O-arm using a device for dose and dose profile scanning measurement”. Tillsammans bildar de ett unikt fingeravtryck.Forskningsoutput
- 1 Doktorsavhandling (sammanläggning)
-
Development and characterization of sensitive, energy-independent solid-state photon dosemeters with high spatial and temporal resolution. Applications in clinical radiology and radiation protection.
Herrnsdorf, L., 2018, Lund: Lund University, Faculty of Medicine. 77 s.Forskningsoutput: Avhandling › Doktorsavhandling (sammanläggning)
Öppen tillgångFil
Projekt
Citera det här
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver