T1 - A portable and low-cost fMRI compatible pneumatic system for the investigation of the somatosensensory system in clinical and research environments
AU - Wienbruch, Christian
AU - Candia, Victor
AU - Svensson, Jonas
AU - Kleiser, Raimund
AU - Kollias, Spyros S
PY - 2006
Y1 - 2006
N2 - There still is a need for devices that allow reproducible stimulation of skin areas of the human body. We constructed a stimulation system and tested it by using brief pneumatic stimulation to the right thumb of nine healthy volunteers. BOLD-signals in response to tactile stimulation with frequencies of 1, 3 and 5 Hz were measured using a 3T MRI scanner. The stimulation device consists of synthetic membranes connected to plastic tubes capable of carrying compressed air, and an electronic component, which controls the on- and off-switching of an electromagnetic valve. The valve near the MR-scanner did not lower the image quality. Primary somatosensory activation contralateral to the stimulation site was reliably detected in response to a stimulus magnitude of 3.5 bar in all volunteers. 1 Hz stimulation resulted in higher maximal percentage BOLD-signal changes. Our device is an easy-to-construct, low-cost and portable tool suitable for research and clinical environments. It permits passive non-painful stimulation relevant for clinical assessments and is also compatible with magnetoencephalography (MEG) and electroencephalography (EEG). In basic and clinical research, this device therefore contributes to meaningful comparisons between results obtained with different techniques.
AB - There still is a need for devices that allow reproducible stimulation of skin areas of the human body. We constructed a stimulation system and tested it by using brief pneumatic stimulation to the right thumb of nine healthy volunteers. BOLD-signals in response to tactile stimulation with frequencies of 1, 3 and 5 Hz were measured using a 3T MRI scanner. The stimulation device consists of synthetic membranes connected to plastic tubes capable of carrying compressed air, and an electronic component, which controls the on- and off-switching of an electromagnetic valve. The valve near the MR-scanner did not lower the image quality. Primary somatosensory activation contralateral to the stimulation site was reliably detected in response to a stimulus magnitude of 3.5 bar in all volunteers. 1 Hz stimulation resulted in higher maximal percentage BOLD-signal changes. Our device is an easy-to-construct, low-cost and portable tool suitable for research and clinical environments. It permits passive non-painful stimulation relevant for clinical assessments and is also compatible with magnetoencephalography (MEG) and electroencephalography (EEG). In basic and clinical research, this device therefore contributes to meaningful comparisons between results obtained with different techniques.
U2 - 10.1016/j.neulet.2006.01.025
DO - 10.1016/j.neulet.2006.01.025
M3 - Article
SN - 0304-3940
VL - 398
SP - 183
EP - 188
JO - Neuroscience Letters
JF - Neuroscience Letters
IS - 3
ER -