TY - JOUR
T1 - Application of SLIPI-based techniques for droplet size, concentration, and liquid volume fraction mapping in sprays
AU - Mishra, Yogeshwar Nath
AU - Tscharntke, Timo
AU - Kristensson, Elias
AU - Berrocal, Edouard
PY - 2020/2/18
Y1 - 2020/2/18
N2 - Structured laser illumination planar imaging (SLIPI)-based techniques have been employed during the past decade for addressing multiple light scattering issues in spray imaging. In this article, SLIPI droplet sizing based on the intensity ratio of laser-induced fluorescence (LIF) over Mie scattering (SLIPI-LIF/Mie) and SLIPI-Scan for extinction-coefficient (μe) mapping are applied simultaneously. In addition, phase Doppler anemometry (PDA) and numerical calculations based on the Lorenz-Mie theory are also employed in order to extract the droplets Sauter mean diameter (SMD), the droplets number density (N), and the liquid volume fraction (LVF) in a steady asymmetric hollow cone water spray. The SLIPI-LIF/Mie ratio is converted to droplets SMD by means of a calibration procedure based on PDA measurements. The droplet SMD for the investigated spray varies from 20 μm to 60 μm, the N values range from 5 to 60 droplets per mm3, and the LVF varies between 0.05 x 10-4 and 5.5 x 10-4 within the probed region of the spray. To generate a series of two-dimensional images at different planes, the spray scanning procedure is operated in a "bread slicing" manner by moving the spray perpendicularly to the light sheet axis. From the resulting series of images, the procedure described here shows the possibility of obtaining three-dimensional reconstructions of each scalar quantity, allowing a more complete characterization of droplet clouds forming the spray region.
AB - Structured laser illumination planar imaging (SLIPI)-based techniques have been employed during the past decade for addressing multiple light scattering issues in spray imaging. In this article, SLIPI droplet sizing based on the intensity ratio of laser-induced fluorescence (LIF) over Mie scattering (SLIPI-LIF/Mie) and SLIPI-Scan for extinction-coefficient (μe) mapping are applied simultaneously. In addition, phase Doppler anemometry (PDA) and numerical calculations based on the Lorenz-Mie theory are also employed in order to extract the droplets Sauter mean diameter (SMD), the droplets number density (N), and the liquid volume fraction (LVF) in a steady asymmetric hollow cone water spray. The SLIPI-LIF/Mie ratio is converted to droplets SMD by means of a calibration procedure based on PDA measurements. The droplet SMD for the investigated spray varies from 20 μm to 60 μm, the N values range from 5 to 60 droplets per mm3, and the LVF varies between 0.05 x 10-4 and 5.5 x 10-4 within the probed region of the spray. To generate a series of two-dimensional images at different planes, the spray scanning procedure is operated in a "bread slicing" manner by moving the spray perpendicularly to the light sheet axis. From the resulting series of images, the procedure described here shows the possibility of obtaining three-dimensional reconstructions of each scalar quantity, allowing a more complete characterization of droplet clouds forming the spray region.
KW - Laser-induced fluorescence (LIF)
KW - Liquid volume fraction (LVF)
KW - Mie scattering (Mie)
KW - Multiple scattering
KW - Sauter mean diameter (SMD)
KW - Sprays
KW - Structured laser illumination planar imaging (SLIPI)
U2 - 10.3390/app10041369
DO - 10.3390/app10041369
M3 - Article
AN - SCOPUS:85081206455
SN - 2076-3417
VL - 10
JO - Applied Sciences (Switzerland)
JF - Applied Sciences (Switzerland)
IS - 4
M1 - 1369
ER -